What it could feel like to press on an auxetic: effect of Poisson’s ratio on the indenter

Author:

Attard DaphneORCID,Gatt Ruben,Caruana-Gauci Roberto,Grima-Cornish James N,Cauchi Reuben,Sillato Darren,Cerasola Dario,Ficarra Giovanni,Bezzina Daniel S,Formosa Cynthia,Gatt Alfred,Grima Joseph NORCID

Abstract

Abstract The behaviour of an indenter having a hard inner core and a softer outer shell, meant to emulate a human finger, pressing upon a sample covered with an isotropic negative/zero/positive Poisson’s top protective layer was investigated through static finite-element simulations. It was shown that if the material being indented had a comparable Young’s modulus to the outer shell of the indenter, a very negative Poisson’s ratio (NPR) results in more pronounced deformations and stresses within the indenter due to the auxetic material offering a higher resistance to indentation. Pressing of an auxetic material with Poisson’s ratio of −0.90 having the same Young’s modulus as that of the softer outer core of the indenter (1 MPa), was found to result in stresses in the indenter which were approximately double to those measured when pressing a conventional material with same Young’s modulus having Poisson’s ratio +0.45. This indicates that auxetics with a very high NPR may feel more uncomfortable when pressed with a finger compared to materials of the same Young’s modulus having a conventional positive Poisson’s ratio (PPR). However, it was also shown that in such scenarios, the auxetic protective layer being indented could be made much thinner whilst still retaining the same functionality. In fact, the simulations suggest that a conventional material with Poisson’s ratio +0.45 indents more than five times as much as an auxetic material with Poisson’s ratio of −0.90 having the same Young’s modulus of 1 MPa. It was also shown that in situations where the material being indented had a much higher Young’s modulus to that of the indenter, the deformations and stresses within the indenter are practically identical irrespective of the Poisson’s ratio, i.e. a human finger is unlikely to be able to perceive the difference between an auxetic and a conventional PPR material.

Funder

Malta Council for Science & Technology

Publisher

IOP Publishing

Subject

Electrical and Electronic Engineering,Mechanics of Materials,Condensed Matter Physics,General Materials Science,Atomic and Molecular Physics, and Optics,Civil and Structural Engineering,Signal Processing

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3