The comparison of two exhaled nitric oxide analyzers: NIOX VERO and SUNVOU-CA2122

Author:

Lei WeiORCID,Li Fei,Tang Xiao-miao,Bian Shuang,Wang Jia-jia,Huang Jian-an

Abstract

Abstract As a marker of eosinophilic airway inflammation, fractional exhaled nitric oxide (FeNO) was widely used in clinical practice. NIOX VERO (VERO) and SUNVOU-CA2122 (CA2122) are two commonly used eNO analyzers in China. However, what’s the difference and agreement between the two devices and whether the two types of devices can be replaced by each other in the application of common respiratory diseases have not been reported. The purpose of this study was to compare the two types of devices and to evaluate the difference between them in clinical use and whether they could be replaced. FeNO levels in 244 respiratory patients (including asthma, chronic obstructive pulmonary disease, chronic cough) were measured by CA2122 analyzer and VERO analyzer, respectively. The FeNO values obtained by the two devices were compared and the differences were analyzed. The success rate, the number of attempts and the total time required for a successful measurement by CA2122 and VERO were compared. The FeNO values measured by CA2122 online and offline were also compared. FeNO values obtained by CA2122 were slightly higher than those of VERO [median(range): 29.0(9–271) parts per billion (ppb) vs 25.5 (5–263) ppb, P = 0.000]. There was a high correlation between FeNO values measured by the two types of devices (r = 0.964, P = 0.000). By comparison, there was a high degree of agreement between the FeNO values measured by two devices, in all patients with different respiratory diseases. FeNO values measured online and offline by CA2122 were highly correlated and there was a high degree of agreement between online and offline methods. The success rate of CA2122 was higher than VERO, and the number of attempts (2.1 vs 2.4) and the total time (110.5 ± 35.7 vs 117.5 ± 48.1 s) required for a successful measurement by CA2122 were lower than those of VERO. CA2122 and VERO can be replaced by each other, and FeNO values can be converted if necessary. CA2122 has some advantages in success rate, the mean attempts and time required for successful measurement of FeNO.

Funder

Science and education of public health project for young medical talents of Jiangsu Province

the Gusu youth medical talent

the Societal and Developmental Project of Suzhou

the Suzhou Key Laboratory for Respiratory Medicine

Publisher

IOP Publishing

Subject

Pulmonary and Respiratory Medicine

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3