A system for contact free energy expenditure assessment under free-living conditions: monitoring metabolism for weight loss using carbon dioxide emission

Author:

Sprowls MarkORCID,Victor Shaun,Serhan Michael,Destaillats Hugo,Wheatley-Guy Courtney,Johnson Bruce,Kulick Doina,Forzani EricaORCID

Abstract

Abstract Weight disorders are strikingly prevalent globally and can contribute to a wide array of potentially fatal diseases spanning from type II diabetes to coronary heart disease. These disorders have a common cause: poor calorie balance. Since energy expenditure (EE) (kcal d−1) constitutes one half of the calorie balance equation (the other half being food intake), its measurement could be of great value to those suffering from weight disorders. A technique for contact free assessment of EE is presented, which only relies on CO2 concentration monitoring within a sealed office space, and assessment of carbon dioxide production rate (VCO2). Twenty healthy subjects were tested in a cross-sectional study to evaluate the performance of the aforementioned technique in measuring both resting EE (REE) and exercise EE using the proposed system (the ‘SmartPad’) and a U.S. Food and Drug Administration (FDA) cleared gold standard reference instrument for EE measurement. For VCO2 and EE measurements, the method showed a correlation slope of 1.00 and 1.03 with regression coefficients of 0.99 and 0.99, respectively, and Bland–Altman plots with a mean bias = −0.232% with respect to the reference instrument. Furthermore, two subjects were also tested as part of a proof-of-concept longitudinal study where EE patterns were simultaneously tracked with body weight, sleep, stress, and step counts using a smartwatch over the course of a month, to determine correlation between the aforementioned parameters and EE. Analysis revealed moderately high correlation coefficients (Pearson’s r) for stress (r average = 0.609) and body weight (r average = 0.597) for the two subjects. The new SmartPad method was demonstrated to be a promising technique for EE measurement under free-living conditions.

Funder

Ira A Fulton Schools of Engineering

Mayo Clinic, Scottsdale

A. J. AND SIGISMUNDA PALUMBO CHARITABLE TRUST

Publisher

IOP Publishing

Subject

Pulmonary and Respiratory Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3