Peppermint protocol: first results for gas chromatography-ion mobility spectrometry

Author:

Ruszkiewicz Dorota MORCID,Myers RenelleORCID,Henderson BenORCID,Yusof Hazim,Meister AustinORCID,Moreno Sergi,Eddleston Michael,Darnley Kareen,Nailon William H,McLaren Duncan,Lao Yvonne E,Hovda Knut ErikORCID,Lam Stephen,Cristescu Simona M,Thomas C L PaulORCID

Abstract

Abstract The Peppermint Initiative seeks to inform the standardisation of breath analysis methods. Five Peppermint Experiments with gas chromatography-ion mobility spectrometry (GC-IMS), operating in the positive mode with a tritium 3H 5.68 keV, 370 MBq ionisation source, were undertaken to provide benchmark Peppermint Washout data for this technique, to support its use in breath-testing, analysis, and research. Headspace analysis of a peppermint-oil capsule by GC-IMS with on-column injection (0.5 cm3) identified 12 IMS responsive compounds, of which the four most abundant were: eucalyptol; β-pinene; α-pinene; and limonene. Elevated concentrations of these four compounds were identified in exhaled-breath following ingestion of a peppermint-oil capsule. An unidentified compound attributed as a volatile catabolite of peppermint-oil was also observed. The most intense exhaled peppermint-oil component was eucalyptol, which was selected as a peppermint marker for benchmarking GC-IMS. Twenty-five washout experiments monitored levels of exhaled eucalyptol, by GC-IMS with on-column injection (0.5 cm3), at t = 0 min, and then at t + 60, t + 90, t + 165, t + 285 and t + 360 min from ingestion of a peppermint capsule resulting in 148 peppermint breath analyses. Additionally, the Peppermint Washout data was used to evaluate clinical deployments with a further five washout tests run in clinical settings generating an additional 35 breath samples. Regression analysis yielded an average extrapolated time taken for exhaled eucalyptol levels to return to baseline values to be 429 ± 62 min (±95% confidence-interval). The benchmark value was assigned to the lower 95% confidence-interval, 367 min. Further evaluation of the data indicated that the maximum number of volatile organic compounds discernible from a 0.5 cm3 breath sample was 69, while the use of an in-line biofilter appeared to reduce this to 34.

Funder

H2020 Security

Publisher

IOP Publishing

Subject

Pulmonary and Respiratory Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3