Device comparison study to measure nasal nitric oxide in relation to primary ciliary dyskinesia

Author:

Jõgi Nils OskarORCID,Ersson KarinORCID,Alving KjellORCID,Krantz ChristinaORCID,Malinovschi Andrei

Abstract

Abstract Primary ciliary dyskinesia (PCD) is a genetic respiratory disease characterized by chronic cough, recurrent respiratory infections, and rhinosinusitis. The measurement of nasal nitric oxide (nNO) against resistance has been suggested as a sensitive screening method. However, current recommendations argue for the use of expensive, chemiluminescence devices to measure nNO. This study aimed to compare nNO measurement using three different devices in distinguishing PCD patients from healthy controls and cystic fibrosis (CF) patients and to evaluate their diagnostic precision. The study included 16 controls, 16 PCD patients, and 12 CF patients matched for age and sex. nNO measurements were performed using a chemiluminescence device (Eco Medics CLD 88sp), and two devices based on electrochemical sensors (Medisoft FeNO+ and NIOX Vero) following standardized guidelines. Correlation estimation, Bland–Altman, ROC curve, and one-way ANOVA were used to assess device differences and diagnostic performance. Significantly lower nNO output values were observed in PCD and CF patients compared to controls during exhalation against resistance. The correlation analysis showed high agreement among the three devices. ROC curve analysis demonstrated 100% sensitivity and specificity at different cut-off values for all devices in distinguishing PCD patients from controls (optimal cut-offs: EcoMedics 73, Medisoft 92 and NIOX 87 (nl min−1 )). Higher nNO output values were obtained with the Medisoft and NIOX devices as compared to the EcoMedics device, with a bias of−19 nl min−1 (95% CI: −73–35) and −21 nl min−1 (−73–31) accordingly. These findings indicate that all three tested devices can potentially serve as diagnostic tools for PCD if device specific cut-off values are used. This last-mentioned aspect warrants further studies and consideration in defining optimal cut-offs for individual device.

Funder

Swedish state under the ALF agreement between the Swedish government and the county councils

Swedish Heart and Lung Foundation

Publisher

IOP Publishing

Subject

Pulmonary and Respiratory Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3