The utility of a standardised breath sampler in school age children within a real-world prospective study

Author:

Bhavra K KORCID,Wilde M,Richardson M,Cordell R,Thomas PORCID,Zhao B,Bryant L,Brightling C E,Ibrahim W,Salman DORCID,Siddiqui S,Monks P,Gaillard E AORCID

Abstract

Abstract Clinical assessment of children with asthma is problematic, and non-invasive biomarkers are needed urgently. Monitoring exhaled volatile organic compounds (VOCs) is an attractive alternative to invasive tests (blood and sputum) and may be used as frequently as required. Standardised reproducible breath-sampling is essential for exhaled-VOC analysis, and although the ReCIVA (Owlstone Medical Limited) breath-sampler was designed to satisfy this requirement, paediatric use was not in the original design brief. The efficacy of the ReCIVA at sampling breath from children has been studied, and 90 breath-samples from 64 children (5–15 years) with, and without asthma (controls), were collected with two different ReCIVA units. Seventy samples (77.8%) contained the specified 1 l of sampled-breath. Median sampling times were longer in children with acute asthma (770.2 s, range: 532.2–900.1 s) compared to stable asthma (690.6 s, range: 477.5–900.1 s; p = 0.01). The ReCIVA successfully detected operational faults, in 21 samples. A leak, caused by a poor fit of the face mask seal was the most common (15); the others were USB communication-faults (5); and, a single instance of a file-creation error. Paediatric breath-profiles were reliably monitored, however synchronisation of sampling to breathing-phases was sometimes lost, causing some breaths not to be sampled, and some to be sampled continuously. This occurred in 60 (66.7%) of the samples and was a source of variability. Importantly, multi-variate modelling of untargeted VOC analysis indicated the absence of significant batch effects for eight operational variables. The ReCIVA appears suitable for paediatric breath-sampling. Post-processing of breath-sample meta-data is recommended to assess the quality of sample-acquisition. Further, future studies should explore the effect of pump-synchronisation faults on recovered VOC profiles, and mask sizes to fit all ages will reduce the potential for leaks and importantly, provide higher levels of comfort to children with asthma.

Funder

MRC and EPSRC Stratified Medicine Grant for Molecular Pathology Nodes

Leicester Wellcome Trust

Publisher

IOP Publishing

Subject

Pulmonary and Respiratory Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3