Author:
ZHU Bangyou,MA Shaoxiang,ZHANG Hongqi,LI Zhiheng,ZHANG Ming,PAN Yuan
Abstract
Abstract
The acceleration grid power supply (AGPS) is a crucial part of the Negative-ion Neutral Beam Injection system in the China Fusion Engineering Test Reactor, which includes a 3-phase passive (diode) rectifier. To diagnose and localize faults in the rectifier, this paper proposes a frequency-domain analysis-based fault diagnosis algorithm for the rectifier in AGPS. First, time-domain expressions and spectral characteristics of the output voltage of the TPTL-NPC inverter-based power supply are analyzed. Then, frequency-domain analysis-based fault diagnosis and frequency-domain analysis-based sub-fault diagnosis algorithms are proposed to diagnose open circuit (OC) faults of diode(s), which benefit from the analysis of harmonics magnitude and phase-angle of the output voltage. Only a fundamental period is needed to diagnose and localize exact faults, and a strong Variable-duration Fault Detection Method is proposed to identify acceptable ripple from OC faults. Detailed simulations and experimental results demonstrate the effectiveness, quickness, and robustness of the proposed algorithms, and the diagnosis algorithms proposed in this article provide a significant method for the fault diagnosis of other rectifiers and converters.
Funder
National Natural Science Foundation of China
National Key R&D Program of China under Grant
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献