A new electromagnetic probe array diagnostic for analyzing electrostatic and magnetic fluctuations in EAST plasmas

Author:

LAN Heng,SHI Tonghui,YAN Ning,LI Xueqin,LI Shi,CHEN Ran,DUAN Moyi,HU Guanghai,LIU Lunan,ZHANG Wei,CHEN Ming,ZHENG Yuanyang,YUAN Zhong,WANG Yong,XU Zhanghou,XU Liqing,ZI PengfeiORCID,CHEN Liang,LIU Shaocheng,WU Donggui,DING Genfan,MENG Lingyi,WANG Zhengchu,ZANG Qing,WU Muquan,ZHU Xiang,HAO Baolong,LIN Xiaodong,GAO Xiang,WANG Liang,XU Guosheng

Abstract

Abstract A novel electromagnetic probe array (EMPA) diagnostic, which consists of a magnetic probe array and an electrostatic probe array, has recently been developed on EAST. The EMPA is fixed near the first wall at horizontal port P. The magnetic probe array of the EMPA consists of 24 identical magnetic probes, each of them capable of measuring toroidal, poloidal and radial magnetic fluctuations simultaneously, providing additional toroidal magnetic fluctuation measurements compared with the regular magnetic probes on EAST. With a higher sampling rate and self-resonant frequency, the EMPA magnetic probes can provide higher frequency magnetic fluctuation measurements. The magnetic probe array of the EMPA is composed of two parallel layers of magnetic probes with a radial distance of 63 mm, and each layer of magnetic probes is arranged in four poloidal rows and three toroidal columns. The compact arrangement of the EMPA magnetic probe array largely improves the toroidal mode number measurement ability from 8 n 8 to 112 n 112 , and also improves the high poloidal wave number measurement ability of magnetic fluctuations compared with the regular high frequency magnetic probes on EAST. The electrostatic probe array of the EMPA consists of two sets of four-tip probes and a single-tip probe array with three poloidal rows and four toroidal columns. It complements the electrostatic parameter measurements behind the main limiter and near the first wall in EAST. The engineering details of the EMPA diagnostic, including the mechanical system, the electrical system, the acquisition and control system, and the effective area calibration, are presented. The preliminary applications of the EMPA in L-mode and H-mode discharges on EAST have demonstrated that the EMPA works well for providing information on the magnetic and electrostatic fluctuations and can contribute to deeper physical analysis in future EAST experiments.

Funder

National Magnetic Confinement Fusion Energy R&D Program of China

National Natural Science Foundation of China

China Postdoctoral Science Foundation

Users with Excellence Program of Hefei Science Center, CAS

Publisher

IOP Publishing

Subject

Condensed Matter Physics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司