Author:
WANG 王 Zhongma 重马,SHI 石 Chaoyi 朝毅,ZHANG 张 Xiuqing 秀青,LU 卢 Wenwu 文武,ZHANG 张 Sheng 胜,GAO 高 Xianhe 先和,XU 许 Tao 涛,SHAO 邵 Xingxing 兴星,HUANG 黄 Liansheng 连生
Abstract
Abstract
In the design realm of fusion power supplies, structural components play a pivotal role in ensuring the safety of fusion devices. To verify the reliability of the converter structure design at the Comprehensive Research Facility for Fusion Technology (CRAFT), meticulous analysis of the converter's dynamic impact is carefully performed based on the worst fault current (400 kA), firstly. Subsequently, the thermal stress analysis based on the maximum allowable steady-state temperature is finished, and the equivalent thermal stress, thermal deformation, maximum shear stress of a single bridge arm and the whole converter are studied. Furthermore, a simple research method involving the current-sharing characteristics of a bridge arm with multi-thyristor parallel connection is proposed using a combination of Simplorer with Q3D in ANSYS. The results show that the current-sharing characteristics are excellent. Finally, the structural design has been meticulously tailored to meet the established requirements.
Funder
National Natural Science Foundation of China
Talent Research Fund of Hefei University