Author:
Ndagi A,Umar A A,Hejazi F,Jaafar M S
Abstract
Abstract
As concrete structures age, concrete quality tends to deteriorate for reasons which include frost damage, acid attack, sulphate attack, fire damage or as a result of bad construction practice. Thus, these effects develop as distresses thereby undermining the general performance of a structure. Result from Ultrasonic Pulse Velocity (UPV) test is inevitably affected by the properties of the concrete under test which contributes in abating the test results. Hence, this paper reviews the UPV test by considering arrangement options and common factors which affect the result obtained from the test and attempts to make recommendations to obtaining reliable results. Out of several conclusions drawn, it is worthy to mention that the direct arrangement for conducting UPV test was found to be the most suitable. In addition, the UPV test was learnt to be poor in assessing concrete strength but when combined with a Rebound Hammer Test, which is also Non-destructive, the result is substantiated.
Reference26 articles.
1. Diagnosis, inspection, testing and repair of reinforced concrete structures;Grantham;Adv Concr Technol,2003
2. Prediction of Self-Compacting Concrete homogeneity by ultrasonic velocity;Benaicha;Alexandria Eng J,2015
3. Review of the ultrasonic pulse velocity: Evaluating concrete compressive strength on site;Hannachi,2014
4. A survey of developments in ultrasonic NDE of concrete;Popovics;IEEE Trans Ultrason Ferroelectr Freq Control,1994
Cited by
25 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献