Author:
Hasan Saif Salah,Baqir Ali Shakir,Mahood Hameed B
Abstract
Abstract
The heat transfer enhancement in terms of temperature of a vertical helically coiled tube heat exchanger is carried out experimentally. The experiments were achieved in a heat exchanger with a 50 cm height and 15 cm internal diameter under four different cold and three hot water mass flow rates and four different airflow rates. At the same time, the temperature difference was taken invariant (ΔT=20°C). To avoid some uncertainties, the hot side temperature of the heat exchanger was measured via k-type thermocouples. The results showed that the increase of air injection flow rate improved heat transfer from the hot stream flowing in the coil to the shell’s cold stream. An intimate thermal mixing when air injected is clearly observed, which could be responsible for the heat exchanger’s thermal enhancement. Finally, the injected air pressure was noticed to be having only a minor effect on thermal performance improvement.
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献