Abstract
During actual operation of the unit, the group efficiency inevitably deviates from the design value and influences the unit heat consumption rate. This paper conduct a series of turbine stage efficiency analysis of the influence of unit energy consumption based on the basic equations for economic analysis, combined with the variable condition of steam turbine model. 1000 MW unit produced by DFSTW as the research object, this paper calculates the load of several groups of different stage group efficiency, and the amount of change of the unit coal consumption. Summarizing, this paper analyses the stage group efficiency influence on the power supply coal consumption rate of the unit, and the variation of stage group efficiency influence on the unit energy consumption with the load change. The results can provide great reference for the operation optimization of thermal power unit.
Reference7 articles.
1. A general equation of indexes for appraising the thermodynamic performance of a steam turbine;Yan;J. Engin. Therm. Energ. Power,2009
2. Research on the unified physical model and mathematic model of heat-economic analysis for the coal-fired power unit;Yan;P. Chinese Soc. Electr. Engin.,2008
3. Comparison and ranking of steam-turbine installations of thermal power-stations’ power-generating units by working efficiency;Farhadzadeh;Therm. Engin.,2018
4. Evaluation of steam turbine unit in thermal power plant based on combination weight and TOPSIS;Wu;Energy Edu. Sci. & Tech. Part A: Energy Science and Research,2014