Characterisation of the auxiliary heating power delivered by the 40 keV neutral beam injectors on the COMPASS tokamak

Author:

Bogar KORCID,Varju JORCID,Havlicek JORCID,Stockel J,Podolnik AORCID,Hron MORCID,Panek RORCID

Abstract

Abstract Two identical neutral beam injectors (NBIs) have been installed on the COMPASS tokamak. Each of them is capable of producing a deuterium (or hydrogen, helium) neutral beam with nominal power of up to 400 kW at 40 keV. Since the COMPASS tokamak is a compact machine, the design of the neutral beams was carefully optimized to fit the neutral beam through the narrow ports of the tokamak. However, once the neutral beams are operated out of the scope of their optimal parameters, additional power losses occur due to neutral beam scraping. This article investigates the amount of power loss due to neutral beam scraping. The losses are calculated using the neutral beam models and measured neutral beam parameters. The calculated results are compared with the measured power delivered into the plasma. Two different neutral beam models are employed. One describes the neutral beam as a sum of small beamlets, which are Gaussian-like. The second one describes the neutral beam as a single Gaussian beam. The amount of the power lost to scraping is determined by both models and compared. Neutral beam parameters, the input parameters for both models, are derived from the Doppler-shifted spectra emitted by fast neutral atoms. It is shown that when operating NBIs at nominal parameters, the scraping losses are negligible ( < 5% ). If the NBIs are operated too far from the nominal parameters, the scraping losses can reach up to ∼60% of the NBI output power. As the highest fractional losses occur with low power NBI, the beam duct is capable of withstanding the corresponding power loads. The expected auxiliary heating power P A U X , the power entering the tokamak chamber carried by fast neutrals, is benchmarked against the additional plasma input power observed in the measured plasma parameters P N B I . The additional plasma input power P N B I is derived from the plasma power balance. The power balance terms are independent of the neutral beam model used for the auxiliary heating power calculation P A U X . The results of the power balance evaluation reveal a difference between two NBIs installed on COMPASS. One of the injectors systematically delivers 17% less power than the other into the plasma given the same beam parameters. It is concluded that the additional losses occur before the beam enters the tokamak chamber.

Funder

COMPASS-U: Tokamak for cutting-edge fusion research

COMPASS Large Infrastructure project

Publisher

IOP Publishing

Subject

Condensed Matter Physics,Nuclear Energy and Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3