Abstract
Abstract
Inductive oil debris monitors can detect wear debris in lubricating oil in real-time, which has great potential for monitoring the working conditions of mechanical systems. However, the superimposition of the induced voltages when multiple debris particles pass through a sensor at a close distance may lead to an erroneous estimation of the peak-to-peak value of the wear debris waveforms. A complete implementation framework is proposed to separate the aliasing signals based on fully convolutional neural networks, which includes a segmented fractional calculus filtering technique and a semi-simulated training dataset generation method. The results of physical experiments indicate that the proposed method can reduce the average error rate of the peak-to-peak value from 15.36% to 3.96% and the maximum error rate from 56.33% to 9.27% compared with those before separation. The stability and computing time of this method are also evaluated through physical experiments.
Subject
Applied Mathematics,Instrumentation,Engineering (miscellaneous)
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献