Abstract
Abstract
An x-ray computed tomography (XCT) interlaboratory comparison campaign, involving an aluminium-machined object, whose dimensions (92 × 78 × 63 mm3) are significant for a 225 kV XCT system, was performed for the purpose of investigating the performances of industrial XCT systems for dimensional measurements in terms of accuracy, i.e. precision and trueness, and to evaluate the influence of the measurement protocol (i.e. measurement strategy), of the operator and of the software on the results by comparison to reference measurements. In this campaign, we came to the conclusion that the measurement strategy is predominant, except for distance; that the measurement process is affected by the operator only for cylindricity and coaxiality; that there is no or little influence of the software except for coaxiality and position; and that a volumetric Gaussian filter allows to improve the measurements only for some participants’ measurements Furthermore, different behaviours, in terms of precision and trueness, are observed depending on the type of measurands when performed by different operators. The diameter measurements are reproducible with XCT, lower than 30 µm which corresponds to a subvoxelic factor of 2.5 and the trueness is lower than 22 µm. The distance measurement is also reproducible with XCT, 15 µm which corresponds to a subvoxelique factor of 4.9 and the trueness is 8 µm. For these mesurands, their measurements do not depend on the used XCT system. However, the XCT reproducibility for cylindricity, coaxiality and position is worse as well as of the trueness except for the position which has a trueness of 1 µm. The process measurement should be revised regarding cylindricity and coaxiality measurements. Finally, overall, the ability of the participants to perform measurements with XCT, whatever their system, is statistically comparable except for a few measurements.
Subject
Applied Mathematics,Instrumentation,Engineering (miscellaneous)
Reference15 articles.
1. COFREND—French Confederation for Non Destructive Evaluation
2. Corrigendum to ‘x-ray computed tomography: from medical imaging to dimensional metrology’ [Precis Eng 60 (2019) 544–569];Villarraga-Gómez;Precis. Eng.,2021
3. Effect of the number of projections on dimensional measurements with X-ray computed tomography;Villarraga-Gómez;Precis. Eng.,2020
4. Accuracy (trueness and precision) of Measurement Methods and Results, Part 2: Basic Method for the Determination of Repeatability and Reproducibility of a Standard Measurement Method,2019
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献