Improving sub-pixel accuracy in ultrasound localization microscopy using supervised and self-supervised deep learning

Author:

Zhang Zeng,Hwang Misun,Kilbaugh Todd J,Katz JosephORCID

Abstract

Abstract With a spatial resolution of tens of microns, ultrasound localization microscopy (ULM) reconstructs microvascular structures and measures intravascular flows by tracking microbubbles (1–5 μm) in contrast enhanced ultrasound (CEUS) images. Since the size of CEUS bubble traces, e.g. 0.5–1 mm for ultrasound with a wavelength λ = 280 μm, is typically two orders of magnitude larger than the bubble diameter, accurately localizing microbubbles in noisy CEUS data is vital to the fidelity of the ULM results. In this paper, we introduce a residual learning based supervised super-resolution blind deconvolution network (SupBD-net), and a new loss function for a self-supervised blind deconvolution network (SelfBD-net), for detecting bubble centers at a spatial resolution finer than λ/10. Our ultimate purpose is to improve the ability to distinguish closely located microvessels and the accuracy of the velocity profile measurements in macrovessels. Using realistic synthetic data, the performance of these methods is calibrated and compared against several recently introduced deep learning and blind deconvolution techniques. For bubble detection, errors in bubble center location increase with the trace size, noise level, and bubble concentration. For all cases, SupBD-net yields the least error, keeping it below 0.1 λ. For unknown bubble trace morphology, where all the supervised learning methods fail, SelfBD-net can still maintain an error of less than 0.15 λ. SupBD-net also outperforms the other methods in separating closely located bubbles and parallel microvessels. In macrovessels, SupBD-net maintains the least errors in the vessel radius and velocity profile after introducing a procedure that corrects for terminated tracks caused by overlapping traces. Application of these methods is demonstrated by mapping the cerebral microvasculature of a neonatal pig, where neighboring microvessels separated by 0.15 λ can be readily distinguished by SupBD-net and SelfBD-net, but not by the other techniques. Hence, the newly proposed residual learning based methods improve the spatial resolution and accuracy of ULM in micro- and macro-vessels.

Funder

National Institute of Neurological Disorders and Stroke

Publisher

IOP Publishing

Subject

Applied Mathematics,Instrumentation,Engineering (miscellaneous)

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3