Traceable frequency measurements with counters

Author:

Piester DirkORCID,Staliuniene EgleORCID,Bauch AndreasORCID

Abstract

Abstract Received signals from Global Navigation Satellite Systems (GNSS) are nowadays widely used by industry laboratories for ensuring metrological traceability for their respective range of calibration services in the field of time and frequency. Usually, a local frequency standard is steered by continuous GNSS signal reception providing at its output stable and accurate reference signals for the laboratory measurement equipment, in general for synthesizers and counters. Reception of GNSS signals is surely an adequate and practical tool for the purpose, however further steps are needed to establish traceability in a strict metrological sense. Based on already available guidelines and publications, this paper is a contribution to the discussion how metrological traceability to internationally accepted standards can be established in a calibration laboratory. We restrict the discussion to equipment in common use which may not necessarily be of the highest sophistication. In this spirit, we develop a detailed scheme for an uncertainty budget comprising all links of the traceability chain from the device under test to the SI second, the scale-unit of Coordinated Universal Time. Then we go through and apply this scheme step by step to a demonstration setup for frequency measurements with a counter with varying operational parameters. In this framework, a novel approach to distinguish between components of statistical measurement uncertainty is introduced. Furthermore, the limiting uncertainty contributions are discussed and based on a suitable set of parameters an expression for the best measurement capability is given. With this scheme at hand a user may develop an uncertainty budget adapted to his own setup, especially if acceptance from a national accreditation body is sought.

Publisher

IOP Publishing

Reference35 articles.

1. General requirements for the competence of testing and calibration laboratories (ISO/IEC 17025:2017);Deutsches Institut für Normung e. V.,2018

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Hardware computing module for frequency Ω-counter;Measurement;2024-04

2. Comparing Frequency Transfer via GNSS and Fiber in a Common-Clock Configuration;The Precise Time and Time Interval Systems and Applications Meeting;2024-02-15

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3