Parametric study of intensity-ratio-based phosphor thermometry using Mg4FGeO6:Mn4+ for instantaneous temperature measurement

Author:

Cheng Weilun,Liu Yingzheng,Peng DiORCID

Abstract

Abstract Intensity-ratio-based phosphor thermometry is advantageous for instantaneous temperature measurement because it avoids interframe displacement due to moving phosphor coated samples that is encountered with lifetime-based methods. This study was aimed at investigating the effects of exposure time, excitation energy, and wavelength on intensity-ratio-based phosphor thermometry using Mg4FGeO6:Mn4+ (MFG). First, the temperature-dependent emission spectra of MFG were obtained under 355 nm and 405 nm excitations. The spectra exhibited different trends in the two cases, potentially because of thermally enhanced phonon-assisted absorption. Next, the shot-to-shot calibration uncertainties were evaluated from the temperature calibration results under different exposure time and excitation irradiance/fluence values for light-emitting diode/laser. The uncertainties under 355 nm and 405 nm excitations exhibited similar trends, i.e. they increased and decreased with increasing temperature and exposure time, respectively. For the minimum exposure time of 4 μs under 355 nm excitation, the uncertainty increased from 1.5 K at 323 K to 3.3 K at 673 K at a constant excitation fluence of 3.14 mJ cm−2. The uncertainties under 405 nm excitation were higher than those under 355 nm excitation. In addition, the inaccuracies due to excitation non-uniformity were evaluated from the calibration results under different excitation irradiance/fluence. The calibration curves were more sensitive to excitation irradiance at higher temperatures under 405 nm excitation. Consequently, the excitation non-uniformity induced inaccuracies under 405 nm excitation and different exposure time values were small at low temperatures (0.4–1.1 K at 323 K) and increased rapidly with temperature (2.6–14.4 K at 673 K). In the case of 355 nm excitation, the calibration curves exhibited small sensitivity to excitation fluence only at low temperatures. As the temperature increased, the inaccuracies under 355 nm excitation decreased and then increased, and exhibited values between 0.5 K and 2.5 K.

Funder

National Natural Science Foundation of China

Shanghai Rising Star Program

Publisher

IOP Publishing

Subject

Applied Mathematics,Instrumentation,Engineering (miscellaneous)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3