Transcutaneous innervation zone imaging from high-density surface electromyography recordings

Author:

Liu Yang,Zhang Chuan,Dias Nicholas,Chen Yen-Ting,Li Sheng,Zhou PingORCID,Zhang YingchunORCID

Abstract

Abstract Objective. It is of great value to accurately localize innervation zones (IZs) to better diagnose and treat neuromuscular diseases, but it is challenging to do so noninvasively from surface electromyography (sEMG) recordings because of the blurring/distorting effect of the low conductive fat tissues. This study aimed to develop an innovative transcutaneous IZ imaging (TIZI) technique to precisely and efficiently localize the IZ distribution directly over the muscle surface in vivo from high-density sEMG recordings (HD-sEMG). Approach. The TIZI technique was implemented by incorporating HD-sEMG recording, signal decomposition, finite element analysis and inverse calculation. The performance of TIZI was evaluated on the flexor digitorum superficialis (FDS) muscle with simulated sEMG signal and experimental signal recorded from both healthy (n  =  3) and stroke participants (n  =  4). The accuracy of imaging was validated by both of the Pearson correlation coefficient (PCC) and localization error (LE) between the TIZI results and the ‘true’ IZ distribution. Main results. In the simulation study, results have shown PCCs of 99.85%  ±  0.11%, 99.79%  ±  0.08%, 99.63%  ±  0.22% and 99.31%  ±  0.54% at the depth of 10, 15, 20 and 25 mm and SNR of 25 dB. PCCs of 98.74%  ±  1.78% and 97.82%  ±  1.20% were respectively obtained for experimental signals acquired from the healthy and spastic FDS muscles. The TIZI provided smaller LEs of 1.4  ±  0.92 mm and 2.02  ±  1.3 mm, compared to LEs of 7.42  ±  2.29 mm and 7.8  ±  1.77 mm from skin observations in healthy and spastic FDS, respectively. Significance. Results have demonstrated the high performance of the proposed TIZI technique by transcutaneous imaging of the IZ distribution of the skeletal muscles. The performance improvement can be attributed to the elimination of the blurring/distorting effect caused by the low conductive fat and high conductive skin tissues. TIZI may provide an advanced neurological tool for the clinical treatment of neuromuscular diseases, such as guiding botulinum neurotoxin injections in spasticity management.

Funder

National Center for Medical Rehabilitation Research

Publisher

IOP Publishing

Subject

Cellular and Molecular Neuroscience,Biomedical Engineering

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3