Abstract

Abstract Objective. Suboptimal electrode placement during subthalamic nucleus deep brain stimulation (STN DBS) surgery may arise from several sources, including frame-based targeting errors and intraoperative brain shift. We present a computer algorithm that can accurately localize intraoperative microelectrode recording (MER) tracks on preoperative magnetic resonance imaging (MRI) in real-time, thereby predicting deviation between the surgical plan and the MER trajectories. Approach. Random forest (RF) modeling was used to derive a statistical relationship between electrophysiological features on intraoperative MER and voxel intensity on preoperative T2-weighted MR imaging. This model was integrated into a larger algorithm that can automatically localize intraoperative MER recording tracks on preoperative MRI in real-time. To verify accuracy, targeting error of both the planned intraoperative trajectory (‘planned’) and the algorithm-derived trajectory (‘calculated’) was estimated by measuring deviation from the final DBS lead location on postoperative high-resolution computed tomography (‘actual’). Main results. MR imaging and MERs were obtained from 24 STN DBS implant trajectories. The cross-validated RF model could accurately distinguish between gray and white matter regions along MER trajectories (AUC 0.84). When applying this model within the localization algorithm, the calculated MER trajectory estimate was found to be significantly closer to the actual DBS lead when compared to the planned trajectory recorded during surgery (1.04 mm vs 1.52 mm deviation, p < 0.002), with improvement shown in 19/24 cases (79%). When applying the algorithm to simulated DBS trajectory plans with randomized targeting error, up to 4 mm of error could be resolved to <2 mm on average (p < 0.0001). Significance. This work presents an automated system for intraoperative localization of electrodes during STN DBS surgery. This neuroengineering solution may enhance the accuracy of electrode position estimation, particularly in cases where high-resolution intraoperative imaging is not available.

Funder

A. Alfred Taubman Medical Research Institute

Department of Neurosurgery, University of Michigan

Publisher

IOP Publishing

Subject

Cellular and Molecular Neuroscience,Biomedical Engineering

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3