Artificial referred sensation in upper and lower limb prosthesis users: a systematic review

Author:

Gonzalez MichaelORCID,Bismuth Alex,Lee ChristinaORCID,Chestek Cynthia AORCID,Gates Deanna HORCID

Abstract

Abstract Objective. Electrical stimulation can induce sensation in the phantom limb of individuals with amputation. It is difficult to generalize existing findings as there are many approaches to delivering stimulation and to assessing the characteristics and benefits of sensation. Therefore, the goal of this systematic review was to explore the stimulation parameters that effectively elicited referred sensation, the qualities of elicited sensation, and how the utility of referred sensation was assessed. Approach. We searched PubMed, Web of Science, and Engineering Village through January of 2022 to identify relevant papers. We included papers which electrically induced referred sensation in individuals with limb loss and excluded papers that did not contain stimulation parameters or outcome measures pertaining to stimulation. We extracted information on participant demographics, stimulation approaches, and participant outcomes. Main results. After applying exclusion criteria, 49 papers were included covering nine stimulation methods. Amplitude was the most commonly adjusted parameter (n = 25), followed by frequency (n = 22), and pulse width (n = 15). Of the 63 reports of sensation quality, most reported feelings of pressure (n = 52), paresthesia (n = 48), or vibration (n = 40) while less than half (n = 29) reported a sense of position or movement. Most papers evaluated the functional benefits of sensation (n = 33) using force matching or object identification tasks, while fewer papers quantified subjective measures (n = 16) such as pain or embodiment. Only 15 studies (36%) observed percept intensity, quality, or location over multiple sessions. Significance. Most studies that measured functional performance demonstrated some benefit to providing participants with sensory feedback. However, few studies could experimentally manipulate sensation location or quality. Direct comparisons between studies were limited by variability in methodologies and outcome measures. As such, we offer recommendations to aid in more standardized reporting for future research.

Funder

National Institute of Neurological Disorders and Stroke

Publisher

IOP Publishing

Subject

Cellular and Molecular Neuroscience,Biomedical Engineering

Reference95 articles.

1. Closed-loop control in prosthetic systems: historical perspective;Childress;Ann. Biomed. Eng.,1980

2. Sensory feedback in upper limb prosthetics;Antfolk;Expert Rev. Med. Devices,2013

3. Getting a grip on the impact of incidental feedback from body-powered and myoelectric prostheses;Gonzalez;IEEE Trans. Neural Syst. Rehabil. Eng.,2021

4. The role of feed-forward and feedback processes for closed-loop prosthesis control;Saunders;J. NeuroEng. Rehabil.,2011

5. Understanding the role of haptic feedback in a teleoperated/prosthetic grasp and lift task;Brown,2013

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3