Coupled Eulerian–Lagrangian model prediction of neural tissue strain during microelectrode insertion

Author:

O’Sullivan K PORCID,Coats BORCID

Abstract

Abstract Objective. Implanted neural microelectrodes are an important tool for recording from and stimulating the cerebral cortex. The performance of chronically implanted devices, however, is often hindered by the development of a reactive tissue response. Previous computational models have investigated brain strain from micromotions of neural electrodes after they have been inserted, to investigate design parameters that might minimize triggers to the reactive tissue response. However, these models ignore tissue damage created during device insertion, an important contributing factor to the severity of inflammation. The objective of this study was to evaluate the effect of electrode geometry, insertion speed, and surface friction on brain tissue strain during insertion. Approach. Using a coupled Eulerian–Lagrangian approach, we developed a 3D finite element model (FEM) that simulates the dynamic insertion of a neural microelectrode in brain tissue. Geometry was varied to investigate tip bluntness, cross-sectional shape, and shank thickness. Insertion velocities were varied from 1 to 8 m s−1. Friction was varied from frictionless to 0.4. Tissue strain and potential microvasculature hemorrhage radius were evaluated for brain regions along the electrode shank and near its tip. Main results. Sharper tips resulted in higher mean max principal strains near the tip except for the bluntest tip on the square cross-section electrode, which exhibited high compressive strain values due to stress concentrations at the corners. The potential vascular damage radius around the electrode was primarily a function of the shank diameter, with smaller shank diameters resulting in smaller distributions of radial strain around the electrode. However, the square shank interaction with the tip taper length caused unique strain distributions that increased the damage radius in some cases. Faster insertion velocities created more strain near the tip but less strain along the shank. Increased friction between the brain and electrode created more strain near the electrode tip and along the shank, but frictionless interactions resulted in increased tearing of brain tissue near the tip. Significance. These results demonstrate the first dynamic FEM study of neural electrode insertion, identifying design factors that can reduce tissue strain and potentially mitigate initial reactive tissue responses due to traumatic microelectrode array insertion.

Publisher

IOP Publishing

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3