Development of a miniaturized, reconnectable, and implantable multichannel connector

Author:

Choi Gwang JinORCID,Yoo Hyun JiORCID,Cho YoonKyungORCID,Shim Shinyong,Yun SeunghyeonORCID,Sung JaehoonORCID,Lim YoonseobORCID,Jun Sang BeomORCID,Kim Sung JuneORCID

Abstract

Abstract Objective. Connectors for implantable neural prosthetic systems provide several advantages such as simplification of surgery, safe replacement of implanted devices, and modular design of the implant systems. With the rapid advancement of technologies for neural implants, miniaturized multichannel implantable connectors are also required. In this study, we propose a reconnectable and area-efficient multichannel implantable connector. Approach. A female-to-female adapter was fabricated using the thermal-press bonding of micropatterned liquid crystal polymer films. A bump inside the adapter enabled a reliable electrical connection by increasing the contact pressure between the contact pads of the adapter and the inserted cable. After connection, the adapter is enclosed in a metal case sealed with silicone elastomer packing. With different sizes of the packings, leakage current tests were performed under accelerated conditions to determine the optimal design for long-term reliability. Repeated connection tests were performed to verify the durability and reconnectability of the fabricated connector. The connector was implanted in rats, and the leakage currents were monitored to evaluate the stability of the connector in vivo. Main results. The fabricated four- and eight-channel implantable connectors, assembled with the metal cases, had a diameter and length of 6 and 17 mm, respectively. Further, the contact resistances of the four- and eight-channel connectors were 53.2 and 75.2 mΩ, respectively. The electrical contact remained stable during repeated connection tests (50 times). The fabricated connectors with packings having 125%, 137%, and 150% volume ratios to the internal space of the metal case failed after 14, 88, and 14 d, respectively, in a 75 °C saline environment. In animal tests with rats, the connector maintained low leakage current levels for up to 92 d. Significance. An implantable and reconnectable multichannel connector was developed and evaluated. The feasibility of the proposed connector was evaluated in terms of electrical and mechanical characteristics as well as sealing performance. The proposed connector is expected to have potential applications in implantable neural prosthetic systems.

Funder

Defense Acquisition Program Administration of Korea

The Korea government

project BK21 FOUR

Korea government

Publisher

IOP Publishing

Subject

Cellular and Molecular Neuroscience,Biomedical Engineering

Reference51 articles.

1. Distribution of speech recognition results with the Clarion cochlear prosthesis;Kessler;Ann Otol. Rhinol. Laryngol.,1995

2. Design for a simplified cochlear implant system;An;IEEE Trans. Biomed. Eng.,2007

3. The surprising performance of present-day cochlear implants;Wilson;IEEE Trans. Biomed. Eng.,2007

4. Mechanisms and targets of deep brain stimulation in movement disorders;Johnson;Neurotherapeutics,2008

5. Motor cortex stimulation for pain and movement disorders;Arle;Neurotherapeutics,2008

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3