Feasibility of endovascular stimulation of the femoral nerve using a stent-mounted electrode array

Author:

Liu JingYangORCID,Grayden David BORCID,Keast Janet RORCID,Booth Lindsea C,May Clive NORCID,John Sam EORCID

Abstract

Abstract Objective. Electrical stimulation of peripheral nerves has long been a treatment option to restore impaired neural functions that cannot be restored by conventional pharmacological therapies. Endovascular neurostimulation with stent-mounted electrode arrays is a promising and less invasive alternative to traditional implanted electrodes, which typically require invasive implantation surgery. In this study, we investigated the feasibility of endovascular stimulation of the femoral nerve using a stent-mounted electrode array and compared its performance to that of a commercially available pacing catheter. Approach. In acute animal experiments, a pacing catheter was implanted unilaterally in the femoral artery to stimulate the femoral nerve in a bipolar configuration. Electromyogram of the quadriceps and electroneurogram of a distal branch of the femoral nerve were recorded. After retrieval of the pacing catheter, a bipolar stent-mounted electrode array was implanted in the same artery and the recording sessions were repeated. Main Results. Stimulation of the femoral nerve was feasible with the stent-electrode array. Although the threshold stimulus intensities required with the stent-mounted electrode array (at 100–500 µs increasing pulse width, 2.17 ± 0.87 mA–1.00 ± 0.11 mA) were more than two times higher than the pacing catheter electrodes (1.05 ± 0.48 mA–0.57 ± 0.28 mA), we demonstrated that, by reducing the stimulus pulse width to 100 µs, the threshold charge per phase and charge density can be reduced to 0.22 ± 0.09 µC and 24.62 ± 9.81 µC cm−2, which were below the tissue-damaging limit, as defined by the Shannon criteria. Significance. The present study is the first to report in vivo feasibility and efficiency of peripheral nerve stimulation using an endovascular stent-mounted electrode array.

Funder

Office of Naval Research

The University of Melbourne

National Health and Medical Research Council of Australia

Microsystems Technology Office

Congressionally Directed Medical Research Programs

Publisher

IOP Publishing

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3