Author:
Burns D T,Kessler C,Jinjie Wu,Peiwei Wang
Abstract
A key comparison has been made between the air-kerma standards of the NIM and the BIPM in the low-energy x-ray range. The results show the standards to be in agreement at the level of the combined standard uncertainty of 3.7 parts in 103. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database.
KEY WORDS FOR SEARCH
Radiation dosimetry, key comparison, low-energy x-rays, air kerma
Main text
To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.
The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).