Dynamic contact stress and frictional heat analysis of femoral head-on-acetabular cup interface based on calculation and simulation methods

Author:

Fang Xingxing,Li Dahan,Xin Yucheng,Wang Songquan,Guo Yongbo,Hu Ningning,Zhang Dekun

Abstract

Purpose The purpose of this paper is to systematically study the dynamic contact stress, frictional heat and temperature field of femoral head-on-acetabular cup contact pairs in a gait cycle. Design/methodology/approach In this paper, four common femoral head-on-acetabular cup contact pairs are used as the research objects, mathematical calculations and finite element simulations are adopted. The contact model of hip joint head and acetabular cup was established by finite element simulation to analyze the stress and temperature distribution of the contact interface. Findings The results show that the contact stress of the head-on-cup interface is inversely proportional to the contact area; high contact stress directly leads to greater frictional heat. However, hip joints with metal-on-polyethylene or ceramic-on-polyethylene paired interfaces have lower frictional heat and show a significant temperature rise in one gait cycle, which may be related to the material properties of the acetabular cup. Originality/value Previous studies about calculating the interface frictional heat always ignore the dynamic change process in the contact load and the contact area. This study considered the dynamic changes of the contact stress and area of the femoral head-on-acetabular cup interface, and four common contact pairs were systematically analyzed.

Publisher

Emerald

Subject

Surfaces, Coatings and Films,General Energy,Mechanical Engineering

Reference29 articles.

1. Development of a novel in silico model to investigate the influence of radial clearance on the acetabular cup contact pressure in hip implants;Materials,2018

2. High-tech hip implant for wireless temperature measurements in vivo;PloS One,2012

3. Frictional heating of total hip implants. Part 2: finite element study;Journal of Biomechanics,2001

4. Hip contact forces and gait patterns from routine activities;Journal of Biomechanics,2001

5. Realistic loads for testing hip implants;Bio-Medical Materials and Engineering,2010