Author:
Deng Shuangjiu,Li Chang,Han Xing,Yu Menghui,Sun Han
Abstract
Purpose
The restoration and strengthening of QT600 is an industry bottleneck challenge. The Co-12 cladding layer has great wear and corrosion resistance. The purpose of this paper is to quantitatively reveal the transient evolution law of the corrosion process of Co-12 cladding layer on QT600 surface.
Design/methodology/approach
In this paper, a three-dimensional numerical model of the corrosion process of Co-12 cladding layer by QT600 laser cladding is established. The interaction between pitting pits and corrosion medium is considered to reveal the transient evolution of ion concentration, electrode potential, pH and corrosion rate at different locations.
Findings
The calculation shows that the ion concentration in pitting pit changes Cl−>Co2+>Na+, pH value decreases from top to bottom and corrosion rate at bottom is greater than that at top. The electrochemical corrosion test of Co-12 cladding layer was carried out. It is shown that the current density of QT600 increases by an order of magnitude compared to the Co-12 cladding layer, and the corrosion rate is 4.862 times higher than that of the cladding layer.
Originality/value
The results show that Co-12 cladding layer has great corrosion resistance, which provides an effective way for QT600 protection.
Reference24 articles.
1. Improved pitting corrosion resistance of stainless steel 304 by lupine extract in hydrochloric acid[J];International Journal of Electrochemical Science,2022
2. A new perspective on measuring the corrosion rate of localized corrosion[J];Materials and Corrosion,2020
3. Origins of pitting corrosion[J];Corrosion Engineering, Science and Technology,2004
4. Study on the properties of the laser cladded cobalt-based alloy coating on T10 tool steel[J];Key Engineering Materials,2011