Purpose
– The purpose of this investigation was to study these problems and design regional cathodic protection, using numerical simulation. Regional cathodic protection technology is immature at home and abroad. This is reflected in the fact that in gas stations, there are many underground pipelines, which can lead to serious interference and shielding phenomena, and there are many grounding networks that can cause substantial loss of the cathodic protection current.
Design/methodology/approach
– Based on the above, in this article, first of all, the mathematical model of the buried pipeline cathodic protection potential distribution was established and the control equations solved using the boundary element method. Second, the cathodic shielding effect in pipeline concentration areas, the effect of instrument equipment grounding systems on cathodic protection and the influence of DC stray current on the interference of pipeline corrosion were studied separately using BEASY software. Finally, the BEASY software was used for a regional cathodic protection design for a real gas station.
Findings
– It was concluded that impressed current used in combination with sacrificial anodes for regional cathodic protection design is often the most economic and effective approach. However, the output current of the auxiliary anode is large with high energy consumption. In consequence, it may be recommended that the station pipelines should be laid on the ground, rather than under it.
Originality/value
– It is considered that the results can guide regional cathodic protection design for real-life installations very well.
Subject
General Materials Science,General Chemical Engineering
Reference23 articles.
1. Bertolini, L.
,
Carsana, M.
and
Pedeferri, P.
(2007), “Corrosion behavior of steel in concrete in the presence of stray current”,
Corrosion Science
, Vol. 49 No. 3, pp. 1056-1068.
2. Brichau, F.
and
Deconinck, J.
(1994), “A numerical model for cathodic protection of buried pipes”,
Corrosion
, Vol. 50 No. 1, pp. 40-49.
3. Brichau, F.
,
Deconinck, J.
and
Driesens, T.
(1996), “Modeling of underground cathodic protection stray currents”,
Corrosion
, Vol. 52 No. 6, pp. 480-488.
4. Chen, H.Y.
,
Fan, Z.G.
,
Liu, L.L.
,
Liu, G.C.
,
Chen, J.
and
Jiao, W.
(2005), “The application of local cathodic protection technology in gas transmission station”,
Oil. & Gas Storage and Transportation
, Vol. 24 No. 5, pp. 41-44.
5. Chen, J.
(2009), “Numerical simulation of local cathodic protection and optimization research on anode location in gas transmission station”, working paper, Southwest Petroleum University, Sichuan, April.
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献