Author:
Zhang Rui,Zhao Lei,Xie Dan,Song Jinlong,Zhang Wendong,Pan Lihu,Zhang Yanhua
Abstract
Purpose
This study aims to simulate and test the performance of a transmitting and receiving capacitive micro-machined ultrasonic transducer (CMUT). Aimed at detecting demand of the CMUT, a matched integrated adjustment circuit was designed through analyzing processing methods of transducer’s weak echo signal.
Design/methodology/approach
Based on the analysis of CMUT array structure and work principle, the CMUT units are designed and the dynamic performance analysis of SIMULINK is given according to the demand of underwater detecting. A transceiver isolation circuit is used to make transmission mode and receiving mode separate. A detection circuit is designed based on the transimpedance amplifier to achieve extraction of high-frequency and weak signal.
Findings
Through experimentation, the effectiveness of the CMUT performance simulation and the transceiver integrated adjustment circuit were verified. In addition, the test showed that CMUT with 400 kHz frequency has wider bandwidth and better dynamic characteristics than other similar transducers.
Originality/value
This paper provides a theoretical basis and design reference for the development and application of CMUT technology.
Subject
Electrical and Electronic Engineering,Industrial and Manufacturing Engineering
Reference28 articles.
1. Integrated circuits for volumetric ultrasound imaging with 2-D CMUT arrays;IEEE Transactions on Biomedical Circuits and Systems,2013
2. Fabrication of linear array and top-orthogonalto-bottom electrode CMUT arrays with a sacrificial release process;IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control,2017
3. A capacitive micromachined ultrasonic transducer probe for assessment of cortical bone;IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control,2014
4. Design, fabrication and characterization of a capacitive micromachined ultrasonic probe for medical imaging;IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control,2005
5. Trapping, separating, and palpating microbead clusters in droplets and flows using capacitive micromachined ultrasonic transducers (CMUTs);Sensors & Actuators: B. Chemical,2018
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献