Real-time wound management through integrated pH sensors: a review
Author:
Khan Munezza Ata,Ansari Umar,Ali Murtaza Najabat
Abstract
Purpose
– Real-time monitoring of wound or injured tissues is critical for speedy recovery, and the onset of a cascade of biochemical reactions provides potential biomarkers that facilitate the process of wound monitoring, e.g. pH, temperature, moisture level, bacterial load, cytokines, interleukins, etc. Among all the biomarkers, pH has been known to have a profound impact on the wound healing process, and is used to determine the incidence of bacterial infection of the wound (persistently elevated alkaline pH), proteolytic activity at the site of injury, take rate in skin grafting, wound healing stage and preparation for wound debridement.
Design/methodology/approach
– This review highlights the significance of pH in determination of clinical parameters and for selection of an appropriate treatment regime, and it presents an in-depth analysis of the designs and fabrication methods that use integrated pH sensors, which have been reported to date for the real-time monitoring of wound healing.
Findings
– For an expedited wound healing process, the significance of pH mandated the need of an integrated sensor system that would facilitate real-time monitoring of healing wounds and obviate the requirement of redressing or complicated testing procedures, which are both labor-intensive and painful for the patient. The review also discussed different types of sensor systems which were developed using hydrogel as a pH-responsive system coupled with voltammetry, potentiometry, impedimetric and flex-circuit inductive transducer systems. All of the mentioned devices have considerable potential for clinical applications, and there is need of in vivo testing to validate their efficiency and sensitivity under practical scenarios.
Originality/value
– This manuscript is an original review of literature, and permission has been granted to use the figures from previously published papers.
Subject
Electrical and Electronic Engineering,Industrial and Manufacturing Engineering
Reference42 articles.
1. Baldi, A.
,
Pan, T.
,
Siegel, R.A.
and
Ziaie, B.
(2004), “A hydrogel-based wireless chemical sensor”, 17th IEEE International Conference on Micro Electro Mechanical Systems, Maastricht MEMS 2004 Technical Digest, IEEE, pp. 391-394. 2. Delode, J.
,
Rosow, E.
,
Roth, C.
,
Adams, J.
and
Langevin, F.
(2001), “A wound-healing monitoring system”,
ITBM-RBM
, Vol. 22 No. 1, pp. 49-52. 3. Gc, G.
(2008), “Wound epair and regeneration”,
Nature
, Vol. 453, pp. 314-321, Doi: 10.1038/nature07039 4. Gerlach, G.
,
Guenther, M.
,
Sorber, J.
,
Suchaneck, G.
,
Arndt, K.F.
and
Richter, A.
(2005), “Chemical and pH sensors based on the swelling behavior of hydrogels”,
Sensors Actuators B Chemical
, Vols 111/112 Special issue, pp. 555-561. 5. Glibbery, A.
and
Mani, R.
(1992), “pH in leg ulcers”,
International Journal of Microcirculation Clinical and Experimental
, Vol. 2 No. 109, p. 98.
Cited by
27 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|