Abstract
PurposeThe main aim of this study is to examine the behavior of reinforced concrete short columns strengthened using longitudinal near surface mounted (NSM)-carbon fiber reinforced polymer (CFRP) strips.Design/methodology/approachA full 3D-finite element (FE) model was developed using ABAQUS in order to conduct the analysis. The model is first validated based on experimental data available in the literature, and then the effect of concrete compressive strength, number of CFRP strips that are used and the spacing between them were taken in consideration for both concentric and eccentric loading cases. The parametric study specimens were divided into three groups. The first group consisted of unstrengthened columns and served as control specimens. The second group consisted of columns strengthened by longitudinal CFRP strips at two opposite column faces.FindingsThe results of this study are used to develop interaction diagrams for CFRP-strengthened short columns and to develop best-fit equations to estimate the nominal axial load and moment capacities for these strengthened columns. The results showed that the specimens that were strengthened using more longitudinal CFRP strips showed a significant increase in axial load capacity and a significant improvement in the interaction diagram, especially at large load eccentricity values. This result can be justified by the fact that longitudinal strips effectively resist the bending moment that is generated due to eccentric loading. Generally, the process of strengthening using longitudinal strips only has a reasonable effect and it can be typically considered an excellent choice considering the economic aspect when the budget of strengthening is limited.Originality/valueThis research aims at studying the performance of strengthened rectangular reinforced concrete short columns with CFRP strips using FE method, developing interaction diagrams of strengthened columns in order to investigate the effect of different parameters such as compressive strength (20, 30 and 40 MPa), number of CFRP strips (1, 2, 3 and 4) and the spacing between CFRP strips in terms of the ratio of CFRP center point distance to column outside dimension ratio (0.60, 0.70 and 0.80) on the behavior of strengthened RC columns and improving empirical formulas to predict the nominal axial load and moment capacities of strengthened RC columns. These parameters that directly affect short column load carrying capacity are presented in ACI-318 (2014).
Subject
Building and Construction,Civil and Structural Engineering
Reference32 articles.
1. ABAQUS v.6.20 (2020), “Computer software and online documentation”, in Dassault Systems, Simulia, Providence, RI, Vol. 505.
2. Building code requirements for structural concrete (ACI 318-14) [and] commentary on building code requirements for structural concrete (ACI 318R-14);ACI Committee 318,2014
3. Effectiveness of externally bonded and near surface–mounted CFRP reinforcement in flexural strengthening of RC beams: numerical approach;Practice Periodical on Structural Design and Construction (ASCE),2022
4. Experimental and numerical investigation for compression response of CFRP strengthened shape modified wall-like RC column;Construction and Building Materials,2014
5. Effect of aggregate size on the bond behavior between carbon fiber-reinforced polymer sheets and concrete;Journal of Materials in Civil Engineering,2019