Purpose Reference voltage or current generators are an important requirement for an analog or digital circuit design. Bandgap reference circuits (BGR) are most common way of generating the reference voltage. This paper aims to provide a detailed insight of design of a folded cascode operational amplifier (FC op amp) and a BGR circuit. The complete study flow from design to layout of the circuits on 180 nm semiconductor laboratory (SCL) process leading to bonding diagram for possible tape-out is discussed. This study work has been supported by MeitY, Govt. of India, through Special Manpower Development Project Chip to System Design. Design/methodology/approach This paper provides a detailed insight in design of a FC op amp and a BGR circuit. The complete study flow from design to layout of the two circuits on 180 nm SCL process leading to bonding diagram for possible tape-out is discussed. Section 2 shows the design of FC op amp, beta-multiplier circuit and their simulation results. Section 3 describes the comparison of design of conventional BGR and the proposed BGR with other state-of-art BGR circuits. Section 4 gives the comparison of their performance. The conclusion is given in Section 5. Findings The post-layout simulation of FC op amp show an open-loop gain of 64.5 dB, 3-dB frequency of 5.5 KHz, unity-gain bandwidth of 8.7 MHz, slew rate of 8.4 V/µs, CMRR of 111 dB and power of 25.5µW. Among the two BGR designs, the conventional BGR generated 693 mV of reference voltage with a temperature coefficient of 16 ppm/°C the other BGR, with curvature correction generated 1.3 V of reference voltage with a temperate coefficient of 6.3 ppm/°C , both results in temperature ranging from −40°C to 125°C. The chip layout of the circuits designed on 180 nm SCL process ensures design rule check (DRC), Antenna and layout versus schematic (LVS) clean with metal fill. Research limitations/implications Slew rate, stability analysis, power are important parameters which should be taken care while designing an op amp for a BGR. Direct current gain should be kept higher to reduce offset errors. Input common mode range is decided by the operating temperature range. A higher power supply rejection ratio will reduce BGR sensitivity to supply voltage variations. Input offset should be kept low to reduce BGR error in reference voltage. However, this paper emphasis on the flow from schematic to layout using simulation tools. As part of the study, the bonding diagram for tape-out of BGR and FC design in the given SCL frame size with seal ring is also explored, for possible tape-out. Practical implications Reference voltage or current generators are an important requirement for an analog or digital circuit design. BGR are most common way of generating the reference voltage. This paper provides a detailed insight in design of a FC op amp and a BGR circuit. The complete study flow from design to layout of the circuits on 180 nm SCL process leading to bonding diagram for possible tape-out is discussed. The chip layout of the circuits was designed on 180 nm SCL process ensuring DRC, antenna and LVS clean with metal fill using Cadence virtuoso and Mentor Graphics Calibre simulation tools. Social implications BGR are most common way of generating the reference voltage. This paper gives a detailed insight of a BGR design using a folded-cascode operational amplifier. The FC op amp is biased using a beta multiplier circuit and high-swing cascode current mirror circuit. The paper discuss FC circuit design flow from schematic to layout. Originality/value FC op amp is biased using a beta multiplier circuit and high-swing cascode current mirror. The paper discusses FC design flow from schematic to layout. The circuits were designed on 180 nm SCL technology with 1.8 V of power supply. The post-layout simulation show an open-loop gain of 64.5 dB, 3 dB frequency of 5.5 KHz, unity-gain bandwidth of 8.7 MHz, slew rate of 8.4 V/µs, CMRR of 111 dB and power of 25.5 µW. BGR were designed using FC op amp. The proposed BGR generated 1.3 V of reference voltage with a temperature coefficient of 6.3 ppm/°C in the range from −40°C to 125°C in schematic simulation.

Publisher

Emerald

Subject

Electrical and Electronic Engineering,Industrial and Manufacturing Engineering

Reference19 articles.

1. A 0.0025 mm2 bandgap voltage reference for 1.1V supply in standard 0.16μm CMOS,2012

2. A CMOS bandgap reference circuit with Sub-1-V operation;IEEE Journal of Solid-State Circuits,1999

3. Designing CMOS folded-cascode operational amplifier with flicker noise minimisation;Microelectronics Journal,2001

4. A novel wide-temperature-range, 3.9 ppm/°C CMOS bandgap reference circuit;IEEE Journal of Solid-State Circuits,2012

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. High-Speed CBJT Operational Amplifier Based on “Folded” Cascode with a Differentiating Transient Correction Circuit;2024 Wave Electronics and its Application in Information and Telecommunication Systems (WECONF);2024-06-03

2. Segment-compensated Bandgap Reference Generator with Low-temperature Drift;Journal of Physics: Conference Series;2024-06-01

3. Circuit Engineering of GaAs Op Amps with Class-AB Push-Pull Output Stage on n-Channel JFets and pnp Bipolar Junction Transistors;2024 26th International Conference on Digital Signal Processing and its Applications (DSPA);2024-03-27

4. An improved 1.8 V 4.05 ppm/°C curvature corrected bandgap reference circuit;Analog Integrated Circuits and Signal Processing;2024-01-30

5. Design of capacitor feedback amplifier for amplifying ECG signal using a folded-cascode amplifier;2023 IEEE 6th International Conference on Information Systems and Computer Aided Education (ICISCAE);2023-09-23