Author:
Fu Ming,Weng Wenguo,Yuan Hongyong
Abstract
Purpose
– The purpose of this paper is to measure the thermal insulation of protective clothing with multilayer gaps in low-level heat exposures.
Design/methodology/approach
– Nine different combinations of protective clothing systems with multiple air gaps are used to measure the thermal insulation by a self-designed bench-scale test apparatus in different levels of an external thermal radiation of 2-10 kW/m2. The outside and inside surface temperatures of each fabric layer are also measured to calculate the local thermal insulation of each fabric layer and each air gap.
Findings
– The results show that the total thermal insulation of protective clothing under thermal radiation is less than that in normal environments, and the exposed thermal radiation will worsen the total thermal insulation of the multilayer fabric systems. Air gap plays a positive role in the total thermal insulation, and thus provides the enhanced thermal protection. It is also suggested that the local resistance of the air gap closer to the external thermal radiation is more easily affected by the thermal radiation, due to the different heat transfer ways in the fabric system and the external thermal radiation.
Originality/value
– Effects of air gap on the thermal insulation of protective clothing, and contribution of the local thermal resistance of each fabric layer and each air gap to the total thermal insulation.
Subject
Polymers and Plastics,General Business, Management and Accounting,Materials Science (miscellaneous),Business, Management and Accounting (miscellaneous)
Reference25 articles.
1. ASTM 1868
(2005), Standard Test Method for Thermal and Evaporative Resistance of Clothing Materials Using a Sweating Hot Plate, American Society for Testing and Materials, West Conshohocken, PA.
2. Celcar, D.
,
Meinander, H.
and
Jelka, G.
(2008), “Heat and moisture transmission properties of clothing systems evaluated by using a sweating thermal manikin under different environmental conditions”, International Journal of Clothing Science and Technology, Vol. 20 No. 4, pp. 240-252.
3. Chen, Y.S.
,
Fan, J.T.
and
Zhang, W.
(2003), “Clothing thermal insulation during sweating”, Textile Research Journal, Vol. 73 No. 2, pp. 152-157.
4. Havenith, G.
,
Holmer, I.
and
Parsons, K.
(2002), “Personal factors in thermal comfort assessment: clothing properties and metabolic heat production”, Energy and Buildings, Vol. 34 No. 6, pp. 581-591.
5. Hes, L.
and
Araujo, L.
(2010), “Simulation of the effect of air gaps between the skin and a wet fabrics on resulting cooling flow”, Textile Research Journal, Vol. 80 No. 14, pp. 1488-1497.
Cited by
19 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献