PurposeThe purpose of this study is to examine the energy savings in the indoor environment, using strategies that adopt the characteristics of nature, called biomimetic solutions. This research designed a biomimetic window system to bring daylight into interior spaces in educational buildings where daylight cannot be reached. Specifically, this study assessed how the daylight that was achieved via a biomimetic window system would affect energy savings using an energy simulation method.Design/methodology/approachThis study explored how biomimetic methods would affect the building environment and which biomimetic method would involve the building's energy saving with daylight. The research intended to develop a novel biomimetic window system that can bring daylight to the basement floor of an existing building on a university campus to find out how much the biomimetic window system would affect the energy savings of the building. Referring to the existing building's layout and structure, energy simulation models were developed, and the energy consumptions were estimated.FindingsSimulation models proved that the biomimetic window system has sufficient performance to bring more daylight to the basement floor of the building. Furthermore, it was confirmed that the use of the biomimetic window system for the building could reduce energy usage compared to the actual energy usage of the current building without biomimetic windows.Research limitations/implicationsFirst, this study was adopted as a computer-designed simulation method instead of using a real-world system. Although this study designed the biomimetic window system based on previous studies, it should be considered the possibility of other problems when the system is actually built in. Second, it is necessary to predict how much an initial budget is required when the system is built. It means that this study did not calculate the lifecycle cost of the biomimetic window system. It will also be necessary to compare energy consumption to the required initial budget. Lastly, this study was simulated based on weather data in cold regions, and it did not compare/analyze different climate regions. Different results may be predicted if the biomimetic window system is built in different climatic regions.Originality/valueThis research showed new practical ways to capture and transmit solar heat and light using a biomimetic solution. Furthermore, using the proposed novel biomimetic window system, the amount of energy reduction can be calculated, and this method could be applied in the interior non-window spaces of academic and related types of buildings.

Publisher

Emerald

Subject

Urban Studies,Geography, Planning and Development,Architecture

Reference63 articles.

1. Whole building energy analysis: a comparative study of different simulation tools and applications in architectural design,2014

2. CN-Peking-Swimming Center 2008-442--26.09.06[.jpg];Wikimedia Commons,2006

3. Integrated multidisciplinary design and construction of the Beijing National Aquatic Centre, China;Structural Engineering International,2011

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3