Influences of domain extensions to a moderately stenosed patient‐specific carotid bifurcation

Author:

Bevan Rhodri,Nithiarasu P.,Sazonov Igor,van Loon Raoul,Luckraz Heyman,Collins Michael,Garnham Andrew

Abstract

PurposeThe purpose of this paper is to numerically study blood flow through a subject‐specific carotid artery with a moderately severe stenosis, also to thoroughly analyse the wall shear stress (WSS), oscillatory shear index (OSI) and WSS angular deviation (WSSAD). One of the important aspects of this study is the investigation on the influence of the extensions attached to the domain outlets.Design/methodology/approachThe segmentation of the carotid artery is carried out using a deformable model based on a level set method. A geometric potential force (GPF) is employed to deform the level set to obtain the carotid artery geometry. The initial surface meshing is generated using an advanced marching cubes (MC) method, before improving the quality of the surface mesh via a number of mesh cosmetic steps. The volume mesh generation has two parts. In the first part, a quasi‐structured, boundary layer mesh is generated in the vicinity of the geometry walls. The second part of the meshing involves unstructured tetrahedral meshing of the inner part of the geometry. After the meshing stage, the flow boundary conditions are generated by numerically solving the Helmholtz equation in both space and time. Finally, the explicit characteristic‐based split (CBS) method is employed in a parallel environment to produce a detailed analysis of wall quantities.FindingsIn general, WSS is very high in the vicinity of the carotid artery apex and in the proximity of the stenosis. From the results obtained, it is clear that the influence of outlet domain extension is marginal. While the peak instantaneous WSS differs by a maximum of 5.7 per cent, the time‐averaged WSS difference due to extended domain is only 1.3 per cent. Two other derived parameters are also examined in the paper, the oscillating shear index and the WSSAD. Both these quantities also display minor or negligible differences due to domain extension.Originality/valueIt has been perceived that domain extension is essential to avoid wrong application of boundary conditions. The results obtained, however, conclusively show that the outlet domain extension has only a moderate influence on WSS. Thus, outlet extension to the domains may not be essential for arterial blood flows. It is also observed that the dramatic values of peak WSS obtained near the stenosis is the result of high resolution mesh along with boundary layers used in this study. Both the outcomes represent the originality of this paper.

Publisher

Emerald

Subject

Applied Mathematics,Computer Science Applications,Mechanical Engineering,Mechanics of Materials

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3