Assessing the quality of retrofits in solid wall dwellings

Author:

Glew DavidORCID,Smith Melanie B.,Miles-Shenton Dominic,Gorse Christopher

Abstract

Purpose The purpose of this paper is to provide a detailed appraisal of the quality of domestic retrofits. Design/methodology/approach This paper presents the results of technical surveys on 51 retrofits undertaken before, during and after the retrofits. Findings Failures are observed to be endemic and characterised into five themes: 72 per cent showed moisture issues pre-retrofit, 68 per cent had moisture risks post-retrofit, 62 per cent did not adopt a whole house approach, 16 per cent showed inadequate quality assurance protocols and 64 per cent showed evidence of insufficient design detailing. Each theme is further subcategorised with a view to identifying implications for future policy. Research limitations/implications The findings suggest the 10 per cent Ofgem retrofit failure rates predictions are an underestimate and so there may be a need for additional investigations to understand the trend across the UK. Practical implications Recommendations to reduce the failure rates may include making changes to the current inspection regime, widening understanding among installers; providing standard repeatable designs for repeated features; and empowering occupants to trigger inspections. Social implications The sample is representative of a substantial proportion of the homes in the UK suggesting that retrofit quality may in many instances be below the required standards. Originality/value Risks of moisture issues and underperformance in domestic retrofit are a concern for government industry and households. This research shows that many installation failures are the result of not implementing existing guidelines and a change to the enforcement of standards may be needed to enact a fundamental change in installer practice and process control.

Publisher

Emerald

Subject

Building and Construction,Civil and Structural Engineering

Reference56 articles.

1. Household energy efficiency headline release executive summary;BEIS,2016

2. BEIS (2017a), “The government response to the ECO: help to heat consultation”, Department for Business, Energy and Industrial Strategy, London.

3. BEIS (2017b), “Household energy efficiency headline release executive summary”, Department for Business, Energy and Industrial Strategy, Statistical Release: National Statistics, London.

4. BIS (2015), “Solid wall insulation; unlocking demand and driving up standards”, BIS, London.

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3