Purpose
The purpose of this paper is to develop a method suitable for the design of reinforced concrete columns subjected to a standard fire.
Design/methodology/approach
The Zone Method – a ’simplified calculation method” included in Eurocode 2 – has been developed by Hertz as a manual calculation scheme for the check of fire resistance of concrete sections. The basic idea is to disregard the thermal strains and to calculate the resistance of a cross-section by reducing the concrete cross-section by a “damaged zone”. It is assumed that all fibers can reach their ultimate, temperature dependent strength. Therefore, it is a plastic concept; the information on the state of strain is lost. The calculation of curvatures and deflections is thus only possible by making further assumptions. Extensions of the zone method toward a general calculation method, suitable for the implementation in commercial design software and using the temperature dependent stress–strain curves of the Advanced Calculation Method, have been developed in Germany. The extension by Cyllok and Achenbach is presented in detail. The necessary assumptions of the Zone Method are reviewed, and an improved proposal for the consideration of the reinforcement in this extended Zone Method is presented.
Findings
The principles and assumptions of the Zone Method proposed by Hertz can be validated.
Originality/value
An extension of the Zone Method suitable for the implementation in design software is proposed.
Subject
Mechanical Engineering,Mechanics of Materials,Safety, Risk, Reliability and Quality
Reference18 articles.
1. Anwendung der Zonenmethode für brandbeanspruchte Stahlbetonstützen;Beton- und Stahlbetonbau,2009
2. Bemessung von Stahlbetonstützen im Brandfall: Absicherung der nicht-linearen Zonenmethode durch Laborversuche;Beton- und Stahlbetonbau,2011
Cited by
10 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献