Abstract
Purpose
For direct torque controlled induction motor drives, an effective solution to eliminate harmonics is the use of multipulse alternating current (AC)-direct current (DC) converters. Many researchers have used different configurations based on 24- and 30-pulse rectifications for improved power quality. However, the total harmonic distortion (THD) of AC mains current with these topology is more than 4 per cent when operating at a light load. For mitigating the THD problems observed in the input currents, Abdollahi propose 40-, 72- and 88-pulse AC-DC converters, while the power quality enhancement was the main concern. It is known that by increasing the number of pulses further results in reduction in current harmonics, but this is accompanied by an increase in cost and complexity. In this context, the purpose of this paper is to design a new delta/hexagon transformer based 36-pulse AC-DC converter for harmonic reduction without increasing the cost and complexity.
Design/methodology/approach
The proposed converter consists of two paralleled 18-pulse AC-DC converters involving a nine-phase shifted uncontrolled diode bridges with an interphase transformer circuit.
Findings
In this paper, the proposed scheme is simulated by matrix laboratory (MATLAB)/SIMULINK considering different loading scenarios. The simulation results show that the proposed scheme improves the power quality indices and satisfies the The Institute of Electrical and Electronics Engineers (IEEE)-519 requirements at the point of common coupling. Also, a laboratory prototype is implemented using the proposed design, and the experimental results confirm the simulation results under different loading conditions.
Originality/value
The proposed solution is a tradeoff among the pulse number, the transformer platform, the complexity of the scheme and the cost. The proposed scheme has an optimized configuration in this regard.
Subject
Electrical and Electronic Engineering,Mechanical Engineering,Mechanics of Materials,Geotechnical Engineering and Engineering Geology,Civil and Structural Engineering
Reference37 articles.
1. Hexagon-connected transformer-based 20-pulse AC–DC converter for power quality improvement;Journal of Electrical Systems,2012
2. Pulse doubling in zigzag-connected autotransformer-based 12-pulse AC-DC converter for power quality improvement;Journal of Electrical Engineering,2012
3. A novel T-connected autotransformer based 30-Pulse AC-DC converter for power quality improvement in direct torque controlled induction motor drives;International Journal of Emerging Sciences,2012
4. Study of delta/polygon-connected transformer-based 36-pulse AC-DC converter for power quality improvement;Archives of Electrical Engineering,2012
5. T-connected autotransformer based 36-pulse AC-DC converter for power quality improvement;Scientific American,2012
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献