Author:
Stoner Brant Edward,Jones Griffin T.,Joshi Sanjay,Martukanitz Rich
Abstract
Purpose
The continued improvement of additive manufacturing (AM) processing has led to increased part complexity and scale. Processes such as electron beam directed energy deposition (DED) are able to produce metal AM parts several meters in scale. These structures pose a challenge for current inspection techniques because of their large size and thickness. Typically, X-ray computed tomography is used to inspect AM components, but low source energies and small inspection volumes restrict the size of components that can be inspected. This paper aims to develop digital radiography (DR) as a method for inspecting multi-meter-sized AM components and a tool that optimizes the DR inspection process.
Design/methodology/approach
This tool, SMART DR, provides optimal orientations and the probability of detection for flaw sizes of interest. This information enables design changes to be made prior to manufacturing that improve the inspectabitity of the component and areas of interest.
Findings
Validation of SMART DR was performed using a 40-mm-thick stainless-steel blade produced by laser-based DED. An optimal orientation was automatically determined to allow radiographic inspection of a thickness of 40 mm with a 70% probability of detecting 0.5 mm diameter flaws. Radiography of the blade using the optimal orientation defined by SMART DR resulted in 0.5-mm diameter pores being detected and indicated good agreement between SMART DR’s predictions and the physical results.
Originality/value
This paper addresses the need for non-destructive inspection techniques specifically developed for AM components.
Subject
Industrial and Manufacturing Engineering,Mechanical Engineering
Reference26 articles.
1. Investigation of laser-welded titanium and stainless steel specimens using digital radiography methods;Russian Journal of Nondestructive Testing,2012
2. Standard practice for manufacturing characterization of digital detector arrays;ASTM,2014
3. Standard practice for determining total image unsharpness and basic spatial resolution in radiography and radioscopy;ASTM,2015
4. Standard practice for radiological examination using digital detector arrays;ASTM,2015
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献