Abstract
PurposeRecent studies have found that the high demand for air-conditioning usage in tropical countries has affected the thermal adaptability of building occupants to hot weather, and increased building energy consumption. This pilot study aims to investigate the effects of transient thermal environment changes on participants' sensory and physiological responses.Design/methodology/approachThe change of thermal perceptions, skin temperatures and core temperatures when exposed to transient thermal environments (cool-warm-cool) from 10 college-aged female participants during a simulated daily commute by foot to class in a tropical university campus were investigated. Subjective measurements were collected in real-time every 5 min.FindingsThe main finding suggests that participants were acclimatised to cool air-conditioned indoor environments, despite exhibiting significant mean skin temperature differences (p < 0.05). In addition, exposure to uniform air conditioning from 17 to 18°C for 20 min was thermally unacceptable and reduced concentration during given tasks.Research limitations/implicationsThe study focused on thermal comfort conditions in a uniform air-conditioned lecture hall, and the findings may not be applicable for residential and other private building spaces. The distinct temperature difference between indoor and outdoor in the tropical built environment resulted in high dependence on air-conditioning usage. The building occupants' well-being and energy conservation implications of the findings are discussed.Practical implicationsThis study provides the platform for discussion on the dynamics of occupants' comfort level and adopting a more variable thermal environment in tropical spatial transient thermal environments among architects and building management system managers. The findings from this study may contribute to the Malaysian Standards for Energy Efficiency and Use of Renewable Energy for Non-Residential Buildings (MS1525).Originality/valueA knowledge gap in adaptive thermal comfort due to exposure from transient conditions in tropical university campus for energy efficiency revision has been investigated.
Subject
Management, Monitoring, Policy and Law,Urban Studies,Building and Construction,Renewable Energy, Sustainability and the Environment,Civil and Structural Engineering,Human Factors and Ergonomics
Reference69 articles.
1. Does the technique employed for skin temperature assessment alter outcomes? A systematic review;Physiological Measurement,2015
2. Field measurements of comfort, seasonal performance and cold stress in cross-laminated timber (CLT) school buildings;Smart and Sustainable Built Environment,2019
3. Analysis of occupant behaviour in the use of air-conditioners in public buildings in developing countries: evidence from Ghana;International Journal of Building Pathology and Adaptation,2020
4. Energy audit and prospective energy conservation: studies at residential college buildings in a tropical region;Facilities,2013
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献