Abstract
Purpose
The purpose of this paper is to investigate the influence and relationship of segment area and opening area in segmented protective pad in comparison to non-segmented pad to the energy absorption and performance attributes relevant to thermophysiological wear comfort.
Design/methodology/approach
The compressive stress-strain curves were obtained using Instron Tester and were used to analyse the energy absorption of the pads and the segmented pad assemblies. The dry thermal resistance and evaporative resistance of the non-segmented and segmented protective pads were obtained using MTNW Sweating Guarded Hot Plate.
Findings
The compression test results and performance attributes relevant to thermophysiological wear comfort test result demonstrated that the area segment and opening area of segmented pad influenced their energy absorption value, dry thermal resistance value and evaporative resistance value (permeability index value).
Originality/value
The results are expected to be useful for design and engineering of hip impact protective garments. Hip impact protective pads are used to prevent hip fractures in elderly people as a result of fall.
Subject
Polymers and Plastics,General Business, Management and Accounting,Materials Science (miscellaneous),Business, Management and Accounting (miscellaneous)
Reference21 articles.
1. Uptake and adherence with soft- and hard-shelled hip protectors in Norwegian nursing homes: a cluster randomised trial;Osteoporosis International,2008
2. Hip fracture prevention: a review;The American Journal of Orthopedics,1998
3. World-wide projections for hip fracture;Osteoporosis International,1997
4. Older adults’ perceptions of wearable technology hip protectors: implications for further research and development strategies;Disability and Rehabilitation: Assistive Technology,2018
5. Etiology and prevention of age-related hip fractures;Bone,1996