Memristor emulator – a nonlinear load for reduction of ferroresonance in a single-phase transformer

Author:

Sridharan Poornima,C. Pugazhendhi Sugumaran

Abstract

PurposeAn annual substation equipment failure report says 3/7 capacitive voltage transformer (CVT) got damaged because of ferroresonance overvoltage. The conventional mitigation circuit fails to protect the transformer as the overvoltage may fall in the range between 2 and 4 per unit. It is necessary to develop a device to suppress the overvoltage as well as overcurrent of the CVT. This study aims to propose the suitability of memristor emulator as a mitigation circuit for ferroresonance.Design/methodology/approachThe literature implies that a nonlinear circuit can protect the transformer against ferroresonance. An attempt is made with a memristor emulator using Operational Amplifier (OPAMP) for the mitigation of ferroresonance in a prototype transformer. The circuit is simulated using PSpice and validated for its ideal characteristics using hardware implementation. The nonlinear memductance is designed which is required to mitigate the ferroresonance. The mitigation performance has been compared with conventional method along with fast Fourier transform (FFT) analysis.FindingsWhile the linear resistor recovers the secondary voltage by 74.1%, the memristor emulator does it by 82.05% during ferroresonance. Also, the total harmonic distortion (THD) of ferroresonance signal found to be 22.06% got improved as 2.56% using memristor emulator.Research limitations/implicationsThe suitability of memristor emulator as a mitigation circuit for ferroresonance is proposed in this paper. As ferroresonance occurs in instrument transformers which have extra high voltage (EHV) rated primary windings and (110 V/[110 V/1.732]) rated secondary windings, the mitigation device is proposed to be connected as a nonlinear load across the secondary windings of the transformer. This paper discusses the preliminary work of ferroresonance mitigation in a prototype transformer. The mitigation circuit may have memristor or meminductor for ferroresonance mitigation when they are commercially available in future.Practical implicationsThe electronic component-based memristor emulator may not work at 110 V practically as they may be rated at low power. Hence, chemical component-based memristor emulator was developed to do the same. The authors like to clarify that the memristor will be a solution for ferroresonance in future not the memristor emulator circuit.Social implicationsWith the real form of memristor, the transistor world will be replaced by it and may have a revolution in the field of electronics, VLSI, etc. This contribution attempts to project the use of memristor in a smaller scale in high-voltage engineering.Originality/valueThe electronic component-based memristor emulator is proposed as a mitigation circuit for ferroresonance. The hypothesis has been verified successfully in a prototype transformer. Testing circuit of memristor emulator involves transformer, practically. The mitigation performance has been compared with conventional method technically and justified with FFT analysis.

Publisher

Emerald

Subject

Electrical and Electronic Engineering,Industrial and Manufacturing Engineering

Reference55 articles.

1. ABB Instrument Transformers (2015), “Instrument transformers – application guide, ABB anon”, Intrument Transformers – application Guide. Available at: https://library.e.abb.com/public/94c2ba5a2f381077c1257df000504e0c/1HSM%209543%2040-00en%20IT%20Application%20Guide%20Ed4.pdf

2. Ferroresonance phenomena in power transformers - Experimental assessment;Journal of King Abdulaziz University-Engineering Sciences,2005

3. Analysis of lightning caused ferroresonance in capacitive voltage transformer (CVT);International Journal of Electrical Power & Energy Systems,2011

4. Initial conditions- related dynamical behaviors in PI- type memristor emulator based canonical chua’s circuit;Circuit World,2018

5. Studying ferroresoance phenomena in actual power systems using bifurcation diagram;Electric Power Systems Research,1999

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3