On the fatigue resistance of endodontic files subjected to electrochemical polishing and an autoclave’s sterilisation cycle

Author:

Santos Pedro,Martins Rui F.,Ginjeira António

Abstract

Purpose The purpose of this paper is to improve the surface finish and, therefore, the fatigue resistance of some endodontic files by electrochemical polishing; the influence of applying an autoclave’s sterilising cycle to the endodontic files under study was also assessed during the research herein presented. Design/methodology/approach In total, 22 Ni-Ti endodontic instruments of two sizes, namely, ref. Hyflex 0.04/20 and 0.06/20 (taper: 0.04; 0.06 and tip diameter: 0.20 mm, respectively), were submitted to rotational bending tests at 500 rpm; the radius and the angle of curvature imposed to the endodontic instruments during the experimental tests were equal to 4.7 mm and 45°, respectively. In addition, 18 endodontic files (out of the 22) were subjected to electrochemical polishing before in vitro fatigue tests had been carried out. Several combinations of electrochemical parameters were considered during the preliminary experiments involving electrolyte, voltage, flow rate and duration. The endodontic files under study were weighted using a high-precision balance before and after polishing, and mass variation was determined. Also, a sterilising cycle was applied to six polished endodontic instruments, which were placed inside an autoclave at 134°C, for 30 min, and under a pressure of 2.16 bar. Findings The fatigue resistance of as-received endodontic files ref. 0.04/20 is much larger (+480 per cent) than the fatigue strength of endodontic files ref. 0.06/20. The weight variation due to electropolishing was comprehended between 0.53 mg and 1.01 mg, and the fatigue resistance of all polished endodontic instruments increased between 30 per cent (0.06/20) and 80 per cent (0.04/20) when compared with the fatigue resistance of the as-received files. The application of an autoclave’s sterilisation cycle had a negative impact on the fatigue resistance of instruments ref. 0.04/20 and a positive impact on the durability of instruments ref. 0.06/20. Originality/value The application of an electrochemical polishing process increased the fatigue resistance of the endodontic files under study significantly, and the values for the variables of the electrochemical process were never published elsewhere. The surface finish improvement was obtained by immersing the endodontic files in a Struers’ Electrolyte (ref. E2) for 3 s while applying 30 volts and a flow rate of 1.

Publisher

Emerald

Subject

Mechanical Engineering,Mechanics of Materials,Civil and Structural Engineering

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Factors influencing NiTi endodontic file separation: A thematic review;Dental and Medical Problems;2024-04-30

2. Effect of various mineral acids during the hydrothermal leaching process of NiTi alloy;Pamukkale University Journal of Engineering Sciences;2023

3. Guest editorial;International Journal of Structural Integrity;2021-11-10

4. Guest editorial;International Journal of Structural Integrity;2021-01-21

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3