Thermal performance of retrofitted secondary glazed windows in residential buildings – two cases from Australia

Author:

Bulut Mehmet BörühanORCID,Wilkinson SaraORCID,Khan Aila,Jin Xiao-HuaORCID,Lee Chyi Lin

Abstract

PurposeThis study presents the results of empirical measurements of the thermal performance of retrofitted secondary glazed windows, involving installation of an additional windowpane, in a residential context in Australia.Design/methodology/approachIn situ temperature measurements were collected from the surfaces of retrofitted secondary glazed windows in two residential buildings in the Australian Capital Territory. The heat loss savings and subsequently the electricity savings were calculated based on these temperature measurements.FindingsHeat loss reductions of up to 60.8% and electricity savings of up to 9.96% could be achieved by retrofitting single glazed windows with secondary glazing. The findings suggest that the thermal performance of retrofitted secondary glazed windows is comparable to double glazed windows.Practical implicationsMultiple glazed windows provide better energy efficiency, thermal and acoustic performance compared to single glazed windows. It is estimated, however, that 85% Australian buildings still have single glazed windows. Secondary glazing has emerged as a cost-efficient and easier-to-install alternative to double glazed windows. The results of this research can contribute to a wider market uptake of secondary glazed windows in Australia by showing that they have similar thermal performance to double glazed windows.Originality/valueThis research is a first attempt to empirically measure the thermal performance of retrofitted secondary glazed windows with an additional windowpane in a residential setting in Australia. Secondary glazing is the provision of an additional windowpane to the original single glazed window. Previous studies in Australia have focused on performance of double glazed windows.

Publisher

Emerald

Subject

Management, Monitoring, Policy and Law,Urban Studies,Building and Construction,Renewable Energy, Sustainability and the Environment,Civil and Structural Engineering,Human Factors and Ergonomics

Reference51 articles.

1. An investigation of flow and conjugate heat transfer in multiple pane windows with respect to gap width, emissivity and gas filling;Renewable Energy,2015

2. Determination of optimum thickness of double-glazed windows for the climatic regions of Turkey;Energy and Buildings,2010

3. Australian Bureau of Meteorology (2020), “Australian capital territory weather and warnings”,available at: http://www.bom.gov.au/act/index.shtml (accessed 15 April 2020).

4. Australian Sustainable Built Environment Council (2016), “Low carbon, high performance”, available at: https://www.asbec.asn.au/research-items/low-carbon-high-performance-report/ (accessed 5 Msy 2021).

5. An infrared thermography passive approach to assess the effect of leakage points in buildings;Energy and Buildings,2017