Author:
Alameeri Ayad,Abdollahzadeh Gholamreza,Hashemiheidari Seyedkomeil
Abstract
Purpose
This study aims to determine the effect of replacing a portion of the cement in the concrete mixture with silica fume (SF) on the corrosion resistance of reinforcing bars, the compressive strength of concrete and the tensile strength of hook bars in both corroded and non-corroded external joints of structures. The external beam-column connection was studied because of its critical role in maintaining structural continuity in all three directions and providing resistance to rotation.
Design/methodology/approach
In external concrete joints, the bars at the end of the beams are often bent at 90° to form hooks that embed in columns. Owing to the importance of embedding distance and the need to understand its susceptibility to corrosion damage from chloride attack, a series of experiments were conducted on 12 specimens that accurately simulate real-site conditions in terms of dimensions, reinforcement and hook bars. SF was replaced with 10% and 15% of the weight of cement in the concrete mixture. To simulate corrosion, the specimens were subjected to accelerated corrosion in the laboratory by applying a low continuous current of 0.35 mA for 58 days.
Findings
The results revealed the effect of SF in improving the compressive strength of concrete, the pullout resistance of the hook bars and the corrosion resistance. In addition, it showed an apparent effect of the corrosion of reinforcing bars in reducing the bonding strength of hook bars with concrete and the effect of SF in improving this strength.
Originality/value
It was noted that the improvement of the results, achieved by replacing 10% of the weight of cement with SF, was significantly close to the results obtained by replacing 15% of the SF. It is recommended that an SF ratio of 10% be adopted to achieve the greatest economic savings.
Reference38 articles.
1. Building code requirements for structural concrete (ACI 318-19) and commentary on building code requirements for structural concrete (ACI 318R-19);ACI Committee 318,2019
2. Anchorage strength of closely spaced hooked bars;ACI Structural Journal,2018
3. Assessment of compressive strength and durability of silica fume-based concrete in acidic environment;Innovative Infrastructure Solutions,2020
4. Corrosion inhibition in reinforced concrete using silica fume immobilized bacterial cells;Journal of Sustainable Cement-Based Materials,2023
5. ASTM G1 – 03: standard practice for preparing, cleaning, and evaluating corrosion test specimens;ASTM,2017