Author:
Norazman Norsafiah,Che-Ani Adi Irfan,Mat Jusoh Hussain Afifuddin Husairi,Wan Ismail Wan Norisma
Abstract
Purpose
The existing concept in the building rating scheme especially in developing countries was more focused on the environment, economic, social and culture. The new approach of the classroom condition index (CCI) assessment scheme has its uniqueness in environmental and social aspects because of high building performance in secondary school buildings. The requirements set by the Ministry of Education Malaysia include providing a conducive learning environment, especially for students who are considered as the main users of classrooms in school buildings. Currently, the school administration needs to manually record the condition of the classroom to increase its comfort level. The lack of a structured scheme for classroom assessment makes it difficult for school administration to focus on the overall classroom condition (physical environmental aspect) in the school building. The purpose of this study is to develop a framework for classroom conditions by proposing a CCI assessment scheme for a secondary school building in Malaysia.
Design/methodology/approach
Mixed methods were used to carry out the study. The first stage of this study concentrates on developing a system for CCI that relates to physical elements in the classroom. This is done by reviewing the literature on the classroom physical performance, as well as a comparison between several building rating systems locally and abroad. The structure of the proposed CCI scheme is grouped into four main themes, namely, space management quality (SMQ), building condition (BC), indoor environmental quality (IEQ) and teaching and learning quality (TLQ). In addition, there are 12 categories and 23 indicators listed under this theme. The second stage focuses on formulating assessment categories with their relevant performance indicators. This phase undergoes a validation process by conducting a survey (questionnaire) toward the classroom’s main users, which are students and teachers. This is to ensure the accuracy of classroom conditions in the school building. A semi-structured interview was also conducted among building experts. They are building surveyors, building engineers, building designers and building performance experts to support the main findings in the second stage. Relative importance (RI) index approach has been applied to show the indicators weighting and ranking are used as data collections method by using Statistical Package of Social Science software to examine the RI of each category and indicator, respectively.
Findings
The findings show that prominent RI and balanced weights are formed from these four main themes. They are SMQ (19.9%), BC (26.6%), IEQ (33.2%) and TLQ (20.3%). The outcome of this study will contribute to a detailed assessment scheme for CCI at the secondary school building. The contribution of the CCI Assessment Scheme is more comprehensive and holistic than the conventional assessment process for BCs. It focuses specifically on classroom space as it is the most important area to achieve a high level of comfort comparing to other spaces in the school building. This holistic approach encompasses all types of classrooms. The concept of one tool fits all is seen as no longer a relevant adaptation in this context. This proposed tool is to be used only for the classroom (as the name CCI implies) and it cannot be used for the other types of spaces, for instance, teacher room, library, meeting room, toilet, canteen and, etc. This is because different spaces represent different physical indicators to be classified. This, in turn, contributes to a conducive learning environment for students in the school.
Originality/value
This paper provides the current information, knowledge and findings related to the classroom physical indicators in developing the assessment scheme for the classroom environment. It will assist both technical and non-technical experts to clarify the current condition of classroom physical performance that ideally may affect the students’ learning environment. The novelty of CCI development is not only on the adopted method but it also includes the ideas on next generation model of rating system that ideally need specific indicators and weighting to be generated into an intelligent computerized system.
Subject
Management of Technology and Innovation,Strategy and Management,Business and International Management
Reference50 articles.
1. Building condition assessment in school using JKR standard;Progress in Engineering Application and Technology,2020
2. The effect of physical environment comfort on employees’ performance in office buildings;Structural Survey,2016
3. Illuminance uniformity using public work department (PWD) standard design for public schools classroom design in Malaysia;Journal of Advanced Research in Fluid Mechanism and Thermal Sciences,2018
4. Comparative assessment of passive design strategies FPR improving indoor themat comfort of low-cost house in hot-humid climate of Malaysia;Journal of Technology,2018
5. Using a calibrated building energy simulation model to study the effects of improving the ventilation in a school;Energy Procedia,2017
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献