Design, development and performance evaluation of pressure sensor using eddy current displacement sensing coil

Author:

K. Gobi,B. Kannapiran,D. Devaraj,K. Valarmathi

Abstract

Purpose The conventional strain gauge type pressure sensor suffers in static testing of engines due to the contact transduction method. This paper aims to focus on the concept of non-contact transduction-based pressure sensor using eddy current displacement sensing coil (ECDS) to overcome the temperature limitations of the strain gauge type pressure sensor. This paper includes the fabrication of prototypes of the proposed pressure sensor and its performance evaluation by static calibration. The fabricated pressure sensor is proposed to measure pressure in static test environment for a short period in the order of few seconds. The limitations of the fabricated pressure sensor related to temperature problems are highlighted and the suitable design changes are recommended to aid the future design. Design/methodology/approach The design of ECDS-based pressure sensor is aimed to provide non-contact transduction to overcome the limitations of the strain gauge type of pressure sensor. The ECDS is designed and fabricated with two configurations to measure deflection of the diaphragm corresponding to the applied pressure. The fabricated ECDS is calibrated using a standard micro meter to ensure transduction within limits. The fabricated prototypes of pressure sensors are calibrated using dead weight tester, and the calibration results are analyzed to select the best configuration. The proposed pressure sensor is tested at different temperatures, and the test results are analyzed to provide recommendations to overcome the shortcomings. Findings The performance of the different configurations of the pressure sensor using ECDS is evaluated using the calibration data. The analysis of the calibration results indicates that the pressure sensor using ECDS (coil-B) with the diaphragm as target is the best configuration. The accuracy of the fabricated pressure sensor with best configuration is ±2.8 per cent and the full scale (FS) output is 3.8 KHz. The designed non-contact transduction method extends the operating temperature of the pressure sensor up to 150°C with the specified accuracy for the short period. Originality/value Most studies of eddy current sensing coil focus on the displacement and position measurement but not on the pressure measurement. This paper is concerned with the design of the pressure sensor using ECDS to realize the non-contact transduction to overcome the limitations of strain gauge type pressure sensors and evaluation of the fabricated prototypes. It is shown that the accuracy of the proposed pressure sensor is not affected by the high temperature for the short period due to non-contact transduction using ECDS.

Publisher

Emerald

Subject

Electrical and Electronic Engineering,Industrial and Manufacturing Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3