The impacts of building opening characteristics on dust particle deposition indoors

Author:

Mohammed Mohammed AlhajiORCID,Bulama Kyari,Bukar Alhaji Modu,Modu Mala Ali,Usman Audu Alhaji,Lawan Alhaji Kasir,Habib Garba Abba

Abstract

PurposeThe effects of dust exposure in buildings and its health and comfort consequences continue to concern occupants, particularly those who spend most of their time indoors. This study examines the influence of building opening characteristics on surface dust loading in indoor environments to determine the dust particles' impact on different opening configurations.Design/methodology/approachIndoor Harmattan dust surface loading data were collected from Maiduguri, Northeastern Nigeria, using model rooms with six different window configurations. A simple mathematical relationship was employed to assess surface dust loading characteristics in the model rooms. The study measured dust thrice between December and February for three days (72 h). The results were analyzed using descriptive statistics.FindingsThe results determined the highest average surface dust loading of 12.03 g/m2 in the room with awning windows at an indoor-to-outdoor (I/O) ratio of 0.7. In contrast, the experiment in the room with a closed window recorded the lowest average surface dust loading of 5.24 g/m2 at an I/O ratio of 0.30, which is infiltration. The outcomes further indicate that the average surface dust loading varies with the building opening type and position, as higher surface dust loadings were recorded in locations closer to the openings (doors and windows), reaffirming that the dominant source of the dust particles is outdoors. According to the study, dust incursion due to infiltration accounts for 30% of the outdoor surface loading.Originality/valueThus, Harmattan dust is a serious challenge to the health, productivity and hygiene of building occupants in the study area. The built-environment professionals must use the study's outcome to optimize building openings' designs (shape, size and form) for effective indoor dust control.

Publisher

Emerald

Subject

Building and Construction,Civil and Structural Engineering

Reference85 articles.

1. The impact of natural ventilation on airborne biocontaminants: a study on COVID-19 dispersion in an open office;Engineering, Construction and Architectural Management,2022

2. Relative contribution of outdoor and indoor particle sources to indoor concentrations;Environmental Science and Technology,2000

3. Heavy metal determination in household dusts from Ilorin City, Nigeria;NISEB Journal,2001

4. Elemental composition of Nigerian Harmattan dust;Journal of Radioanalytical and Nuclear Chemistry Articles,1988

5. Importance-performance analysis (IPA) of the indoor environmental quality (IEQ) of an EDGE-certified building in Ghana;International Journal of Building Pathology and Adaptation,2023

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献