PurposeThis research presents the applicable international fire code requirements for educational facilities, in a comprehensive manner, and the findings of a case study to assess the level of compliance with these requirements.Design/methodology/approachA review of literature, fire codes and standards was conducted to identify the various sources of fire hazards in educational facilities and the required prevention measures. Accordingly, a code-compliance worksheet for assessing the fire prevention measures was developed. The worksheet included 34 prevention measures. It was implemented in a pharmacy college building, as a case study, to assess the compliance level with the code requirements. Recommendations were developed to improve the level of fire prevention in the case study facility.FindingsThe implemented worksheet facilitated identifying all the shortcomings in the prevention measures, in a methodological manner. These shortcomings included exceeded travel distance, absence of assembly point, inactive record keeping of fire inspection and maintenance works, deterioration of some extension cords and switches, alteration of some emergency doors, storage of combustibles in some electrical rooms and obstructions of the fire apparatus access road.Practical implicationsThe research provides an assessment tool for fire prevention in educational facilities, which can be used by professionals for a code-compliant inspection. The findings of the case study as an example serve to expand the inspectors' observational significance while reducing subjectivity.Originality/valueThis research contributes to the educational facilities' context of health and safety domain in the literature. The research classifies the required fire prevention measures for an educational facility, according to the international applicable codes and standards. The case study demonstrates an applicable methodology for assessing the fire prevention measures and requirements.

Publisher

Emerald

Subject

Management Science and Operations Research,Safety Research

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3