Author:
Yuan Zhijie,Wang Hao,Li Rou,Mao Jianxiao,Gao Hui
Abstract
Purpose
This paper aims to investigate the equivalent relationship between accelerated corrosion tests and real environmental spectrum of suspenders in long-span suspension bridge considering multiple factors action.
Design/methodology/approach
Based on Faraday's law, corrosion current was used as a measure of metal corrosion, and the equivalent conversion relationship between laboratory environment and real service environment was established. The equivalent conversion method for bridge structural steel had been determined under different temperature, humidity, pH value and NaCl concentration conditions. The compilation of environmental spectra for large span bridges considering multiple factors and the principle of equivalent conversion have been proposed.
Findings
Environmental factors, including temperature, humidity, pH value and NaCl concentration, have significant impact on the corrosion degree of suspension steel wires, and only considering these two factors for equivalent conversion cannot accurately reflect the true service environment of the bridge. The 33.8-h salt spray accelerated corrosion test using the standard conditions can be equivalent to one year of suspenders corrosion in a real service environment.
Originality/value
The equivalent accelerated corrosion method for steel wires proposed in this study can effectively predict the corrosion degree of the suspenders, which has been verified to be correct and can provide theoretical guidance for the development of corrosion test plans for steel wires and engineering technical basis for anti-corrosion control and calendar life research of suspension bridge suspenders.
Subject
General Materials Science,General Chemical Engineering
Reference36 articles.
1. Accelerated corrosion and embrittlement of high-strength Bridge wire;Journal of Materials in Civil Engineering,2000
2. Bridge stay cable corrosion protection. II: accelerated corrosion tests;Journal of Bridge Engineering,2005
3. Experimental study of corrosion effects on high-strength steel wires considering strain influence;Construction and Building Materials,2020
4. Fatigue life evaluation of high-strength steel wires with multiple corrosion pits based on the TCD;Journal of Constructional Steel Research,2021
5. Corrosion tests in artificial atmospheres—Salt spray tests: GB/T 10125—2021 (2013), “Corrosion tests in artificial atmospheres—Salt spray tests: GB/T 10125—2021”, Standards Press of China, Beijing, in Chinese, pp. 3-5.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献